10 Pin Modular Plug
connects to your terminal
9 Pin Type D Female
onnects to the scanner handle
Turn on good read or LED beeper
9 5 Volt power connection ◆
8 Cord shield
7 Supply ground
6 Laser enable
Some decoders may have +12V on pins 4 or 9. Connect to +5VDC ONLY!
◆ Pins 4 and 9 are populated depending on power supply voltage option.
◆ N/C 4
Trigger signal to decoder 5
Start of scan 1
Digital barcode data output 2
Turn on good read LED or beeper 3
2 Trigger signal to decoder
3 Laser enable
4 Supply ground
5
6 Digital barcode data output
7 Power connection (Refer to table on page 13-1)
8
9 Start of scan
10
1
Conventional laser data format is provided at the modular connector in the scanner handle. The interface cable is terminated with a 10 pin modular plug, and a 9 pin Type D (squeeze to release) connector
that is compatible with all Honeywell terminals.
Standard Cable Pinouts
Laser Output Only (Laser Compatible Bar Image)
13 - 3