Download System 25 R1V1 Reference Manual
Transcript
TABLE 4-D. 23A Asynchronous Data Units (ADUs) Z3A Model Wall Jack Connector RS-232C Connector Z3A1 Modular 4-pair jack Plug-ended (M) 25-pin connector on a 3-foot cable Jacks for single-line voice terminal, wall jack, and Originate/Disconnect switch Z3A2 Modular 4-pair jack Plug-ended (M) 25-pin connector (attached to housing) Jacks for single-line voice terminal, wall jack, and Originate/Disconnect switch Z3A4 Modular 4-pair jack Receptacle-ended (F) 25-pin connector on 3foot cable Jacks for single-line voice terminal, wall jack, and Originate/Disconnect switch Z3A5 Modular 4-pair jack Plug-ended (M) 25-pin connector on 3-foot cable Jacks for required KS-22911 L1 Power Unit, Wall jack, 7300H Series voice terminal, and optional Originate/Disconnect switch Options ADU Connection Information Detailed connection information is provided in the following figures: ● ● ● Figure 4-45—Typical ADU Connections Supporting Data Terminal And Single-Line Voice Terminal Figure 4-46–Typical ADU Connections Supporting Data Terminal And 7300H Series Multiline Voice Terminal Figure 4-47—Typical Z3A1/2/4 ADU Local Power Connections. As shown in Figure 4-47, local external power may be provided to the Z3A1, Z3A2, and Z3A4 ADUs via a 2012D power transformer and a 248B adapter attached to a 400B2 adapter with a D6AP-87 modular cord. Descriptions of the SIP (Station Interconnect Panel), TAE (Trunk Access Equipment), and associated cables and adapters, as shown on the figures, are provided under the heading “Connectivity” later in this Section. 4-49