Download SPC User Manual
Transcript
Technical specifications: 7 Ampere Adjustable Capacity Dynamic range Input max. 8 Ampere 0,5 – 8,0 Ampere 110 V Frequency Temperature sensor Bandwidth range 50 / 60 Hz 4K7 at 77 ºF 33,8 till 44,6 ºF SPC 14 Ampere picture: 4 Fuse Fuse Main Switch Power outlet The system uses a 16A 'slow' fuse. 1 2 3 Technical specifications: 14 Ampere Adjustable Capacity Dynamic range Input max. 16 Ampere 0,5 – 16,0 Ampere 110 V Frequency Temperature sensor Bandwidth range 50 / 60 Hz 4K7 at 77 ºF 33,8 till 44,6 ºF SPC 28 Ampere picture: 4 Fuse Main Switch The system uses 2x a 16A 'slow' fuse. Power outlet 1 2 3 Technical specifications: 28 Ampere Adjustable Capacity Dynamic range Input 2x max.16 Ampere 2x 0,5 – 16,0 Ampere 110 V Frequency Temperature sensor Bandwidth range 50 / 60 Hz 4K7 at 77 ºF 33,8 till 44,6 ºF ATTENTION: Our SPC’s are being programmed for most used fans. However, switching the minimal speed down is possible. For this purpose turn the cal. Min potentiometer (under the socket template on the left hand side). Turn left for minus and right for plus. Turn down the speed in such a manner that the fan will always keep running. TURNING DOWN ANY MORE WILL INCREASE THE POSSIBILITY OF HUMMING FANS. If the SPC is being switched off through the switch (0-position) and then is restarted, first put the switch on 100% and only afterwards on auto. This is being recommended in order to protect the connected fans.