Download User Manual - LUCKINSlive
Transcript
Modbus Plus language objects Implicit Exchange Language Objects Associated with the Application-Specific Function At a Glance An integrated application-specific interface or the addition of a module automatically enhances the language objects application used to program this interface or module. These objects correspond to the input/output images and software data of the module or integrated application-specific interface. Reminders The module inputs (%I and %IW) are updated in the PLC memory at the start of the task, the PLC being in RUN or STOP mode. The outputs (%Q and %QW) are updated at the end of the task, only when the PLC is in RUN mode. NOTE: When the task occurs in STOP mode, either of the following are possible, depending on the configuration selected: outputs are set to fallback position (fallback mode) outputs are maintained at their last value (maintain mode) Figure The following diagram shows the operating cycle of a PLC task (cyclical execution). 66 35006188 10/2014