4. Press the chair tightly till it fully closed as in Figure M3.
XII.Troubleshooting
The control panel will display a number of possible trouble conditions by means
of the LED light.When the LED light is green, the chair is trouble-free. When a
problem occurs, the LED light will flash.
When a “Trouble” LED light flashes, turn off the power of the chair and turn it on
again. If the flashing “Trouble” LED light remains unchanged, please refer to the
table below for possible causes and solutions.
If you cannot determine the cause of the trouble condition, please contact your
provider or distributor for assistance.
No. Trouble
1
Power
Possible cause
Solution
Faulty connection of the
Re-plug the 4-pin plug into
control panel and the motor the battery connector at the
connector
side of the chair.
Low power supply, the
If the power is off
power cut off automatically. automatically, the batteries
must be recharged within
two hours and charged for
10 – 12 hours.
Fault of the 3-pin plug
connecting to the battery.
26
Pull out the battery and
check the contact for any
fault and reinsert the
battery.