3.2.13
Operation P14: Control hydraulic system oil levels
10min
Hex key, funnel, SAE 15-30 grade hydraulic oil
1. The hydraulic system forms a closed circuit, however a slight drop in the oil level may be
noticed. This is normal. As needed, top up the circuit with SAE 15-30 grade hydraulic oil.
2. Open the plug (1).
3. Top up the circuit with oil.
4. Close the plug (the plug is not air-tight).
621058005_indE_RobuROC6_Mai ntenance_Manual