Download PowerPlex® ES System
Transcript
tmd017.0708.qxp 7/25/2008 4:11 PM 9. 1. Page 2 Appendix ...................................................................................................................................44 A. Advantages of STR Typing...........................................................................................44 B. Advantages of Using the Loci in the PowerPlex® ES System .................................44 C. DNA Extraction and Quantitation Methods..............................................................47 D. The Internal Lane Standard 600...................................................................................47 E. PowerPlex® ES Separation Control .............................................................................48 F. Preparing the PowerPlex® ES System Master Mix ...................................................48 G. Composition of Buffers and Solutions........................................................................49 H. Related Products ............................................................................................................49 Description STR (short tandem repeat) loci consist of short, repetitive sequence elements 3–7 base pairs in length (1–4). These repeats are well distributed throughout the human genome and are a rich source of highly polymorphic markers, which may be detected using the polymerase chain reaction (5–8). Alleles of STR loci are differentiated by the number of copies of the repeat sequence contained within the amplified region and are distinguished from one another using radioactive, silver stain or fluorescence detection following electrophoretic separation. The PowerPlex® ES System(a–c) allows co-amplification and three-color detection of nine loci (eight STR loci and Amelogenin), including D18S51, D21S11, TH01, D3S1358, FGA, D8S1179, vWA, Amelogenin and SE33. One primer specific for each of the D18S51, D21S11, TH01 and D3S1358 loci is labeled with fluorescein (FL); one primer specific for each of the FGA, D8S1179, vWA and Amelogenin loci is labeled with carboxy-tetramethylrhodamine (TMR); and one primer specific for SE33 is labeled with 6-carboxy-4´,5´-dichloro-2´,7´-dimethoxy-fluorescein (JOE). All nine loci are amplified simultaneously in a single tube and analyzed in a single injection. The PowerPlex® ES Monoplex System, SE33 (JOE) (Cat.# DC6751) is available to amplify the SE33 locus. This monoplex system allows amplification of a single locus to confirm results obtained with the PowerPlex® ES System and re-amplify DNA samples when one or more of the loci do not amplify initially due to nonoptimal amplification conditions or poor DNA template quality. The PowerPlex® ES System is compatible with the ABI PRISM® 310, 3100 and 3100Avant Genetic Analyzers and Applied Biosystems 3130 and 3130xl Genetic Analyzers. The protocols presented in this manual were tested at Promega Corporation. Amplification and detection instrumentation may vary. You may need to optimize protocols including cycle number and injection time (or loading volume) for each laboratory instrument. In-house validation should be performed. Promega Corporation · 2800 Woods Hollow Road · Madison, WI 53711-5399 USA · Toll Free in USA 800-356-9526 · Phone 608-274-4330 · Fax 608-277-2516 · www.promega.com Part# TMD017 Page 2 Printed in USA. Revised 7/08