25 Park Place - Phase Two Georgia State University 3. 4. D. 3.3 HII 12053-02 GSU 080-096-13 wall. Twist: Plus or minus 1/16" measured at opposite face corners of jambs on parallel lines, and perpendicular to plane of wall. Plumbness: Plus or minus 1/16" measured at jambs on a perpendicular line from head to floor. Coat inside of other frames with bituminous coating to a thickness of 1/16 inch. INSTALLATION A. Install in accordance with the requirements of the specified door grade standard and NAAMM HMMA 840. B. In addition, install fire rated units in accordance with NFPA 80. C. Coordinate frame anchor placement with wall construction. 1. Floor Anchors: Provide floor anchors for each jamb and mullion that extends to floor, and secure with post installed expansion anchors. a. Floor anchors may be set with power actuated fasteners instead of post installed expansion anchors if so indicated and approved on shop drawings. 2. Metal Stud Partitions: Solidly pack mineral fiber insulation behind frames. 3. Masonry Walls: Coordinate installation of frames to allow for solidly filling space between frames and masonry with grout. 4. In-Place Concrete or Masonry Construction: Secure frames in place with post installed expansion anchors. Countersink anchors, and fill and make smooth, flush and invisible on exposed faces. 5. In-Place Gypsum Board Partitions: Secure frames in place with post installed expansion anchors through floor anchors at each jamb. Countersink anchors and fill and make smooth, flush and invisible on exposed faces. 6. Ceiling Struts: Extend struts vertically from top of frame at each jamb to overhead structural supports or substrates above frame unless frame is anchored to masonry or to other structural supports at each jamb. Bend top of struts to provide flush contact for securing to supporting construction. Provide adjustable wedged or bolted anchorage to frame jamb members. February 7, 2014 HOLLOW METAL FRAMES 081213 - 5
Related documents
normas citadas - International Code Council
American Dynamics RAS917LS-1 Specifications
Revestimentos Flutuantes – Processos Construtivos e Patologia
BioMedical - Chart Industries
RIDGID TS2410LS User manual
Smardt Air Cooled Chiller O&M - Coward Environmental Systems
Rheem GAS BOOSTED SOLAR WATER HEATER User's Manual
Charles B. Aycock High School Addition & Renovation
Final Specs Cover 810.psd
ProSceniumDMX - Digimedia MLS
Request for Proposal #196 50 kW Photovoltaic Solar Power System
GENERAL PROVISIONS FOR HEATING