Download INSTALLATION INSTRUCTION

Transcript
CONNECT REFRIGERANT PIPES BETWEEN INDOOR AND OUTDOOR UNITS
Seal Copper Line Set/Wire Cable/Drain Hose Line Combination
CONNECT REFRIGERANT PIPES
Seal Copper Line Set/Wire Cable/Drain Hose Line Combination:
Pipe insulation
Interconnection cable
* Use factory-recommended components, as briefly illustrated below.
* Cover line set in a sequence, either from indoor to outdoor, or the other way.
* Secure line set covers onto the wall using factory-recommended accessories.
Cable tie
LINE SET COVERS
Sealing tape
Pipe
Sealing tape
INSTALLATION OF ACCESSORIES
Not to damage line sets.
Unit front panel
Interconnection cable
Refrigerant pipe
Drain hose
Connecting pipe
Pipe of indoor unit
Interconnection cable
Hanger or
Clamp
Pipe/wire wall
sleeve/ring
Putty (stuffing gaps)
Inside
Pipe
Overlap wrapping
tape..
Cable tie
STRT
COUP
COUP-H
OFST
ELBF90 O
ELBF45 O
SOFT
TEE ENDF
RDER
Wall
Outside
INSTALLER'S
INSTRUCTION
INSTALLER'S
INSTRUCTION
INLTS
* Run cables along with the refrigerating copper line sets and secure them with tapes at 6 feet apart.
* Wrap tape closely (cover a third of the width of the wrapping tape applied early) to ensure good sealing.
* Tape and seal the end of wrapping tape.
* Shape the pipe combination gently, without causing kinking, sharp bending, or other damage to it.
* Fix the pipe combination securely on the external wall with proper clamps, at 6 feet apart.
OUTDOOR UNIT FOOT RISER OR BRACKETS
* Fill the gap between the wall hole and wall sleeve with putty to keep from rain or dust entering inside.
BRKT-XXXX-SC1
* Made of steel.
* Coated with weatherproof polyester powder.
PIPING GUIDE
Set the packed pipes
vertically and then unwind
slowly.
Size(Inch)
Model
Don't unwind only one end
of the coiled pipes.
A
17.7
21.7
BRKT-0918-SC1
BRKT-1860-SC1
LBs
320
360
B
15.4
18.3
Btu/h
09K-18K
18K-60K
A
BRKT-XXXX-ST1
* Made of stainless steel.
Size(Inch)
Model
Use pulley to keep the safe
bending radius..
B
Capacity
Don't make sharp or small
radius bending.
A
17.7
21.7
BRKT-0918-ST1
BRKT-1860-ST1
Capacity
LBs
320
360
B
15.4
18.3
Btu/h
09K-18K
18K-60K
B
A
RIST-XXXX-PVC
May also use rolling wheel to
reduce internal pipe tension
and avoid possible
deformation.
Don't bend too long of a
pipe without tools.
Foot Riser
Accessories: End Caps (Optional)
Use elbow tool to keep
bending radius.
Don't make less than 90
degree bend.
* Shock-proof PVC, Weatherproof & UV resistant.
* Supplied with fastening screws and anchor bolts.
* Easy to install.
* The "honeycomb" structure acts as an anti-vibration
& humming absorption for a quite operation.
Keep minimum bending
radius..
Do not make to sharp of a
bend.
YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !
P29 OF 38
Model
RIST-0918-PVC
RIST-1860-PVC
Size(Inch)
A
14.2
17.7
B
3.7
3.7
C
3.1
3.1
C
B
A
D
Capacity
D
4.1
4.1
LBs
220
260
Btu/h
09K-18K
18K-60K
YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !