Download INSTALLATION INSTRUCTION
Transcript
CONNECT REFRIGERANT PIPES BETWEEN INDOOR AND OUTDOOR UNITS Seal Copper Line Set/Wire Cable/Drain Hose Line Combination CONNECT REFRIGERANT PIPES Seal Copper Line Set/Wire Cable/Drain Hose Line Combination: Pipe insulation Interconnection cable * Use factory-recommended components, as briefly illustrated below. * Cover line set in a sequence, either from indoor to outdoor, or the other way. * Secure line set covers onto the wall using factory-recommended accessories. Cable tie LINE SET COVERS Sealing tape Pipe Sealing tape INSTALLATION OF ACCESSORIES Not to damage line sets. Unit front panel Interconnection cable Refrigerant pipe Drain hose Connecting pipe Pipe of indoor unit Interconnection cable Hanger or Clamp Pipe/wire wall sleeve/ring Putty (stuffing gaps) Inside Pipe Overlap wrapping tape.. Cable tie STRT COUP COUP-H OFST ELBF90 O ELBF45 O SOFT TEE ENDF RDER Wall Outside INSTALLER'S INSTRUCTION INSTALLER'S INSTRUCTION INLTS * Run cables along with the refrigerating copper line sets and secure them with tapes at 6 feet apart. * Wrap tape closely (cover a third of the width of the wrapping tape applied early) to ensure good sealing. * Tape and seal the end of wrapping tape. * Shape the pipe combination gently, without causing kinking, sharp bending, or other damage to it. * Fix the pipe combination securely on the external wall with proper clamps, at 6 feet apart. OUTDOOR UNIT FOOT RISER OR BRACKETS * Fill the gap between the wall hole and wall sleeve with putty to keep from rain or dust entering inside. BRKT-XXXX-SC1 * Made of steel. * Coated with weatherproof polyester powder. PIPING GUIDE Set the packed pipes vertically and then unwind slowly. Size(Inch) Model Don't unwind only one end of the coiled pipes. A 17.7 21.7 BRKT-0918-SC1 BRKT-1860-SC1 LBs 320 360 B 15.4 18.3 Btu/h 09K-18K 18K-60K A BRKT-XXXX-ST1 * Made of stainless steel. Size(Inch) Model Use pulley to keep the safe bending radius.. B Capacity Don't make sharp or small radius bending. A 17.7 21.7 BRKT-0918-ST1 BRKT-1860-ST1 Capacity LBs 320 360 B 15.4 18.3 Btu/h 09K-18K 18K-60K B A RIST-XXXX-PVC May also use rolling wheel to reduce internal pipe tension and avoid possible deformation. Don't bend too long of a pipe without tools. Foot Riser Accessories: End Caps (Optional) Use elbow tool to keep bending radius. Don't make less than 90 degree bend. * Shock-proof PVC, Weatherproof & UV resistant. * Supplied with fastening screws and anchor bolts. * Easy to install. * The "honeycomb" structure acts as an anti-vibration & humming absorption for a quite operation. Keep minimum bending radius.. Do not make to sharp of a bend. YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! P29 OF 38 Model RIST-0918-PVC RIST-1860-PVC Size(Inch) A 14.2 17.7 B 3.7 3.7 C 3.1 3.1 C B A D Capacity D 4.1 4.1 LBs 220 260 Btu/h 09K-18K 18K-60K YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! P30 OF 38