Download TENMAR - Farnell
Transcript
Digital-Contro l and Programmable DC Power Supply Models: 72-2535, 72-2540, 72-2545, 72-2550 & 72-10480 User Manual TENMA R User Manual TENMA R User Manual TENMA R User Manual Table of Contents SAFETY INSTRUCTION ....................... 3 REMOTE CONTROL. . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Safety Symbols ........... .... .. . . . 3 Remote Control Setup. . . . . . . . . . . . . . . 1 4 Remote control procedures . . . . . . . . . . . 1 5 General Introduction ................. 4 AC Input ......................... 4 Fuse Parameters ................... 4 FAQ .................................. ...16 OVERVIEW....................... ....... . . 5 SPECIFICATIONS .. ... . . . . . . . ... .... . . . . . . 17 Models Introduction. . . ....... ......... . . 5 Main Characteristics...... . . . . . . . . . . . . . . 5 Front and Rear Panel Overview..... . . . . . . . 6 FRONT PANEL INTRODUCTION . .... ... . . . . . . 6 .................... 6 Display . ......................... 6 Status Indication ........ ........... 6 Storage Indication . ................. 7 Brief Introduction of Panel Buttons ....... 7 Panel Overview REAR PANEL INTRODUCTION .............. 9 OPERATION .............................. 10 Power Up ............. .. ......... 10 Output ON/OFF ......... .. ......... 11 Beep ON/OFF .......... .. ......... 11 Panel Lock ............ .. ......... 11 Output Parameters Setup . ....... .... . 12 ............... . . . . . . . 12 Recall Setup . .............. . . . . . . . 13 Save Setup 1 2 TENMA R User Manual TENMA R User Manual SAFETY INSTRUCTION SAFETY SYMBOLS Saf et y Gui del ines •Do not block or obstruct the cooling fan vent opening. •Avoid severe impacts or rough handling that leads to damage. This chapter contains important safety instructions that you must follow when operating the Tenma power supply and when keeping it in storage. Read the following before any operation to insure your safety and to keep the best condition for the Tenma power supply. •Do not discharge static electricity . •Do not disassemble unless you are qualifie d as service personnel. AC INPU T ! Safety Symbols These safety symbols may appear in this manual or on the series. ! WARNING DANGER High Voltage。 •Location: Indoor, no direct sunlight, dust free, almost non-conductive pollution (note below) Operation Environment •Relative Humidity: < 80% •Altitude: < 2000m • •Temperature: 0-40℃ Storage environment FU SE ! Earth (ground) Terminal •AC Inut Vol tage : 110V / 120 V / 220 V / 230 V , 50 / 60 Hz •Conn ec t the pr ot ec tive gr oun di ng co ndu ct or of the AC power co rd to an ear th gr oun d, to av oi d el ec trica l sh oc k. •Location: Indoor •Relative Humidity: < 70% •Temperature: -10-70℃− Mode l 72 - 10480 72 - 253 5 72 - 254 0 72 - 254 5 72-2550 110/ 120 V T4A/ 250 V 220 /230 V T2A/ 250 V T5A/ 250 V T3A/ 250 V T5A/ 250 V T5A/ 250 V T3A/ 250 V T3A/ 250 V T5A/250 T3A/250V •To ens ur e fire pr ot ec tion, repl ac e the fus e onl y with the sp ec ified typ e and rat ing. •Disc onn ec t the power co rd bef or e fus e repl ac em ent . •Mak e su re the ca us e of fus e bl owout is fixe d bef or e fus e repl ac em ent . 3 4 TENMA R User Manual Series L i n eu p / Ma in Featu r es Mode l V M e ter A Me t er USB Re s olu t ion 72-10480 4 d igi t 4dig it NO 10 m v /1mA 72 - 2 535 4 di g it 4d i git Yes 1 0 m v / 1m A 72-2540 4di g it 4d i git Yes 1 0 m v / 1mA 72-2545 72-2550 4d i git 4di g it 4digit 4digit Yes Ye s 1 0 m v / 1mA 10mv / 1m A TENMA R User Manual Front Panel Overview TENMA Display of voltage & current value Op e rati o n Pr o tec t io n Inte r fa c es Lo w noise: c oo l ing fa n c on t rolle d by hea t s i nk t emper a ture ; ● Compac t size , lig h t we i g h t. ● C o n s t a nt vo l tage / consta n t c urre n t o perati o n ● Ou tpu t On / O f f Co n trol ● Digi t a l pa n e l co n t ro l ● 4 p a i rs of p a nel set u p sa v e / re c all ● C oarse and fi n e Vo l t age / C u rre nt c on tr ol ● Sof t wa re c ali b rati o n ● Beep o u tput ● Key l ock f u n c t i o n ● Ov erloa d p rote c t i on ● R eve r se p o l a ri ty pro t ection ● USB/RS 2 3 2 for remot e c ont r ol ( only f o r 7 2-2535 ,72 - 2 54 0 , 72 - 25 4 5 , ● 7 2 - 2 5 50 ) DC PROGRAMMABLE SUPPLY 30V 3A OVP V M1 M2 Power Supply Indicator A C.C M3 C.V M4 OUT M5 Over-Volt Protection Active Over-current Protection Active Constant Current Mode Constant Voltage Mode Output On/Off Indicator Setting Memory Indicator MEMORY RECALL/SAVE UNLOCK M1 LOCK Front Panel lock_Out Function Over_current Protect On/Off Buttons for saving & Recalling Buttons for saving &Recalling ADJUST Rapid Adjustment Knob for Voltage & Current BEEP Output On/Off Performanc e R M2 OCP M3 OVP M4 Off /ON POWE R + < > Volgote Current - Coarse and fine Voltage / Current Adjustment Buttons Voltage / Current Selection Earth (Ground) Terminal Power ON / OFF Button Power Output Terminal DISPLAY Voltage level Current level Voltme ter displays the setup value of output voltage . V Di splays the setup value of output current . A Condition Indication OVP OV P is the indicator of overvoltage protection. Wh en overvoltage function is turned on, OVP indicator lights on; wh en output voltage is higher than protection setup value due to unexpected conditions, output cuts off and OV P indicator flickers; Press the key OV P again, and the powe r supply recovers. 5 6 TENMA R User Manual OCP is OCP indicator. When overcurrent function is turned on, indicator lights on. TENMA C. C is con stan t cur ren t ind icat or. Whe n po wer sup pl y is in the mod e of con stan t cur ren t, thi s ligh t is on . C.V C. V is constant voltage indicator. When powe r supply is in the mode of constant voltage, this light is on. OUT OUT is output indicator. If light on, there is voltage output in the output terminal. User Manual UNLOCK Front panel lock_out function. For details, see Page 11. LOCK C.C R BEEP Over-Current protect on/off, Pressing this key for more than 2 seconds will make beep On/OFF. OCP Over-votage Protect On/Off OVP Off /ON Storage Indication Output On/Off . ADJUST Voltage-Current Setting Adjustment M1 M2 M3 Indication of saving an d recalling 5 setups stored internally; < > Digit Selector Buttons M4 Volgote/ Current M5 Brief Introduction of Panel Operation . Selection Voltage / Current for Adjustment Pressing the key, the volt indicator starts to flicker; pressing it again, the ampere indicator starts to flicker. Then turn the key ADJUST and the settings of the setted voltage or current can be adjusted. MEMOR Y RECALL/SAVE M1 POWER M2 M3 Sa ves or recalls panel settings. Fo r settings, 1 ~ 4 are available. Fo r save / recall details, see Pa ge 13. + On / Off main power. For power up sequence, see Page 10. outputs voltage and current. M4 Connects the ground (earth ) terminal. 7 8 TENMA R User Manual TENMA R User Manual OPERATION FNSZ1057-00-00 S/N NO:011062300000000-0000 Fan Co nnecting AC powe r cord and selecting the VOLTAGE RATING: AC 220V FUSE RATING: 2A / 250V Label on Vol tage & Fuse corresponding AC voltage according to the Co nnect AC powe r cord back label on voltage; then connecting the WARNING AC powe r cord to the socket on the back panel TO AVOID ELECTRIC SHOCK, THE POWER CORD PROTECTIVE GROUNDING CONDUCTOR MUST BE CONNECTED TO GROUND. FOR CONTINUED FIRE PROTECTION, REPLACE FUSE WITH 250V FUSE OF THE SPECIFIED TYPE AND RATING. NO OPERATION SERVICEABLE COMPONENTS INSIDE Power Socket DO NOT REMOVE COVE RS; REFE R SERVI CI NG TO QUALI FI ED PERSO NNE L. powe r on POWER Pr ess the powe r swi tch to ma ke powe r on. The display initializes, showi ng the mo del of the ma chine and then showi ng the setting level recalled the last time . POWER The power cord socket mainly accepts AC values: 115V / 230V, 50 / 60 Hz. Please refer to the fuse parameters on the back fuse label to replace the specified fuse. powe r off Press the power switch again to make power off. Mak e su re the co rrec t typ e of fus e is ins tal led bef or e power up 9 10 TENMA R User Manual Pressing the Output key to turn on output; and the key LED also turns on. Pressing the Output key again to turn off the output and the key LED. Note: If there are any of the following conditions, the output will automatically turn off. 1. OVP turns on and there are unusual OVP on the output terminal. 2. The setting voltage is more than that of the OVP. 3. Recalling other setups from the memory. Beep On / Off Panel Operation R User Manual Output Set Output On / Off Panel Operation TENMA Panel operati on 1. Connecti ng the load to the front port, CH 1 + / - . 2. Setting output voltage and current. Press the key Voltage/Current selecti on to switch voltage adjustm ent and current adjustm ent. Adjusti ng voltage and current with Voltage / Current Adjustm ent knob. By default, the Voltage and Current knob work in the coarse mode. To acti vate the fine mode, press the keys to select the coarse mode or the fine mode. 3. Turning on the output and pressing the output key. The key LED turns on and displays CV or CC mode. SAVE / RECALL SETUP By default, the beep sound is enabled. To turn off the beep, press the OCP(BEEP) key for 2 seconds. A beep comes out and the beep setting will be turned off. To enable the beep, press the OCP(BEEP) key again for 2 seconds. Save Setup Background The front panel settings can be stored into one of the four internal memories. Contents The following list shows the setup contents.。 ●Fine / coarse knob editing mode ●Beep on / off ●Output voltage / current level The following settings are always saved as "off ". ● Output on / off ● Front panel lock on / off Panel operation Press one of the 4 buttons (M1,M2,M3,M4) and the LED light turns on accordingly.After you adjust the value,it is saved automatically once it stop s blinking. Front Panel Lock Panel operation Press the LOCK key to lock the front panel key operation. The key LED turns on. To unlock, press the LOCK key for 2 seconds. 11 12 TENMA R User Manual TENMA R User Manual REMOTE CONTROL Recal l Set up Remote Control Setup Th e front pan el set tings can be recal led from one of the four int er nal mem or ies. All the models 72-2535,72-2540,72-2545,72-2550 etc. can be connected to the PC through interfaces USB/RS232 on the back of the machine and controlled by the remote control. MEM ORY LECALL/SAVE M1 M2 M3 COM setting Press any but ton of M1 to M4, and take M1 for exam pl e; the mem or y of pan el set tings is recal led in M1. After you recal l M4, rot at e the shut tle knob and then M5 is recal led. Set up the COM port inside the PC accordingto the following list. • Baud rate: 9600 • Parity bit: None M4 • Data bit: 8 • Stop bit: 1 • Data flow control: None M1 M2 M3 M4 It means the current memory is recalled that the memory indicator on the panel lights on accordingly. M5 Note Functionality Run this query command via the terminal check application such as MTTTY (Multi-threaded TTY). *IDN? This should return the identification information: Manufacturer, model name, serial number. 72 - 10480 SN:xxxxxxxx Vx.xx When a set ting is recal led, the out put aut om at ical ly tur ns off . 13 14 TENMA R User Manual TENMA R User Manual REMOTE CONTROL PROCEDURES FAQ Entering the Remote Control Mode Q1: Th e pane l but tons don' t wor k when pow er on. 1.Connecting USB 2.The power supply will automatically connect. After A1: Th e pa ne l is loc ked . Pr es s the key the pa ne l wi ll un loc k. LOCK UNLOCK for ov er 2 sec on ds , an d the n normal connection, there will be a tweet from the Q2: Pressi ng ON/OFF, ther e is no out put when pow er on. power supply itself. 3.The panel keys are locked, so the power supply can only A2: Cur ren t set up is 0. rely on the remote control. Q3: Out put vol tage rises sl ow ly when out put but ton is on. A3: Cur ren t set up is too smal l. Exiting from the Remote Control Mode 1.Closing the remote control software. 2. Disconnecting USB from the back. Q4: Maki ng OCP on and pr essi ng out put sw itch; and then the out put is aut om at ical ly shut off . A4: Cur ren t pr ot ec tion val ue set up is too smal l. You cou ld pr es s ou tpu t swi tch an d the n mak e OC P on . 3. The power supply disconnects; a tweet from the beep with the hint that the remote control is over. 4. The power supply automatically comes into the panel control mode. 15 16