Download CE EMC TEST REPORT

Transcript
Reference No.: 90616202-E
Report No.: T120907D10-E
7.3. RADIATED EMISSION MEASUREMENT
7.3.1. LIMITS
Below 1GHz
dBuV/m (At 10m)
FREQUENCY (MHz)
Class A
40
47
30 ~ 230
230 ~ 1000
Class B
30
37
Above 1GHz
Frequency (MHz)
1000 ~ 3000
3000 ~ 6000
Class A (dBuV/m) (At 3m)
Average
Peak
56
76
60
80
Class B (dBuV/m) (At 3m)
Average
Peak
50
70
54
74
NOTE: The lower limit shall apply at the transition frequencies.
According to EN 55022: 2010 clause 6.2, the measurement frequency range shown in the following
table:
Highest frequency generated or used within the EUT or
on which the EUT operates or tunes (MHz)
Upper frequency of measurement range
(MHz)
Less than 108
1000
108-500
2000
500-1000
5000
Above 1000
5 times of the highest frequency or 6GHz,
whichever is less
Page 17 / 56
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.