Download CE EMC TEST REPORT
Transcript
Reference No.: 90616202-E Report No.: T120907D10-E 8.4.5. TEST RESULTS Temperature 18oC Humidity 58% RH Pressure 1008mbar Dwell Time 3 sec. Tested By David Cheng Required Passing Performance Criterion A Frequency (MHz) Polarity Azimuth Field Strength (V/m) Observation Result 80 ~ 1000 V&H 0 3 Note PASS 80 ~ 1000 V&H 90 3 Note PASS 80 ~ 1000 V&H 180 3 Note PASS 80 ~ 1000 V&H 270 3 Note PASS NOTE: There was no change compared with the initial operation during the test. Page 38 / 56 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.