Download Technical Description EOSINT P 390 Technical Description
Transcript
Technical Description EOSINT P 390 1.3 Recoating unit Recoating system for generation of a new powder layer, fed by powder supply container, surface equalisation with overflow container. - Minimum layer thickness 0.1 mm - Layer thickness variation < 0.05 mm Left and right powder supply containers with powder fluidisation and dispenser units - Capacity of container about 45 litres each Vertical control of process platform via precision spindle drive - Repetition accuracy over a 300 mm distance 1.4 ± 0.05 mm Heating, process chamber Building process heaters in the upper and lower building chamber are operated separately. Both heater circuits are separately controlled. - Infrared radiator (short wave) 3.2 kW - Readout of actual/set value 1.5 via digital display Nitrogen generator NG-3H (integrated protective gas generator with cooling) The protective nitrogen generator separates compressed air into nitrogen and oxygen. The nitrogen produced is used for cooling the optics and as a protective gas for the process. Oxygen is allowed to flow into the ambient and will prevent high nitrogen concentrations from becoming hazardous for the operating personnel. - Total air consumption (Vn) about 10 m³/h - Purity of N2 > 99 % - N2 output rate (Vn) at purity 99 % < 1.5 m³ at 6 bar EOS GmbH - Electro Optical Systems Robert-Stirling-Ring 1 D-82152 Krailling / München FP / 06.11.2006 TD_P390_en.doc 3 / 20 Telephone: +49 (0)89 / 893 36-0 Telefax: +49 (0)89 / 893 36-285 Internet: www.eos.info