Download Combi-Modul 515

Transcript
Inputs/Outputs
5 Inputs and Outputs
5.1 Analog Inputs
The standard configuration of the COMBI-Modul 515 provides 4
analog inputs with an input voltage range of 0...10V and a resolution
of 10 bit. The board makes use of the C515C on-chip A/D converter
unit. The microcontroller ports P6.0 to P6.3 are used to connect the
on-board circuitry to the A/D converter. Each analog input provides a
overvoltage protection circuitry.
Analog Input
AIN0
AIN1
AIN2
AIN3
Table 23:
Microcontroller Port
P6.0
P6.1
P6.2
P6.3
Analog Inputs
The phyPS Modul driver provide functions to read analog signals.
This enables easy processing of these values in user‘s software.
For further information on the analog inputs and processing the signals refer to the controller User‘s Manual/Datasheet.
 PHYTEC Elektronik GmbH 2000
L-335e_2
39