Download Combi-Modul 515
Transcript
Inputs/Outputs 5 Inputs and Outputs 5.1 Analog Inputs The standard configuration of the COMBI-Modul 515 provides 4 analog inputs with an input voltage range of 0...10V and a resolution of 10 bit. The board makes use of the C515C on-chip A/D converter unit. The microcontroller ports P6.0 to P6.3 are used to connect the on-board circuitry to the A/D converter. Each analog input provides a overvoltage protection circuitry. Analog Input AIN0 AIN1 AIN2 AIN3 Table 23: Microcontroller Port P6.0 P6.1 P6.2 P6.3 Analog Inputs The phyPS Modul driver provide functions to read analog signals. This enables easy processing of these values in user‘s software. For further information on the analog inputs and processing the signals refer to the controller User‘s Manual/Datasheet. PHYTEC Elektronik GmbH 2000 L-335e_2 39