AMETEK Programmable Power
4.5
Array Measurement Subsystem
MX Series SCPI Programming Manual
[3Pi Controller Only]
This command subsystem lets you retrieve arrays containing measurement data. Only
current and voltage measurements are stored in an array. Two measurement commands
are available: MEASure and FETCh. A MEASure command triggers the acquisition of new
data before returning the readings from the array. A FETCh command returns previously
acquired data from the array.
Individual outputs of a three-phase source are specified by the setting of
INSTrument:NSELect.
Subsystem Syntax
MEASure | FETCh
:ARRay
:CURRent
[:DC]?
:HARMonic
[:AMPLitude]?
:PHASe?
:MODE
:VOLTage
[:DC]?
:HARMonic
[:AMPLitude]?
:PHASe?
54
Returns the digitized instantaneous current
Returns amplitudes of the first 50 harmonics
Returns phase angles of the first 50 harmonics
Selects waveform data transfer format
Returns the digitized instantaneous voltage
Returns amplitudes of the first 50 harmonics
Returns phase angles of the first 50 harmonics
MX Series