SVmco User Guidel Severity: Error Action: (R/M/T/S) 18502 SV RAID:%2 Adapter error (BBU temperature above threshold) vendorid=1000/1734 device-id=%d revision=%r Meaning: An abnormal battery temperature was detected. %2: Device name %d: (Example) 0060/10F9 (device-id/sub device-id) %r: Numerical value (1 to 3 digits) Corrective action: 1. When the SAS disk unit has free space, confirm that no dummy is mounted. 2. Confirm that the temperature of the operating environment satisfies the specified values. 3. Confirm that the latest RAID controller and firmware are installed. 4. If the error recurs, collect investigation materials (e.g., fjsnap, PrimeCollect), and contact your sales representative or a field engineer. Severity: Error 902