Download WebRelay-10 Users Manual
Transcript
WebRelay-10 Users Manual Appendix F: SNMP Requests, Objects and Community Strings the temperature boundaries are crossed. See 2.3.9 Sensor Tab for more information on configuring the sensor alarms. Object Description Value web10.65 Sensor one alarm. x.x (Decimal temperature or humidity.) web10.66 Sensor two alarm. x.x (Decimal temperature or humidity.) Web10.67 Sensor three alarm. x.x (Decimal temperature or humidity.) Web10.68 Sensor four alarm. x.x (Decimal temperature or humidity.) Web10.69 Sensor five alarm. x.x (Decimal temperature or humidity.) Web10.70 Sensor six alarm. x.x (Decimal temperature or humidity.) Web10.71 Sensor seven alarm. x.x (Decimal temperature or humidity.) Web10.72 Sensor eight alarm. x.x (Decimal temperature or humidity.) Password WebRelay-10™ uses the Control Password for both the read and write community strings. If the Control Password is disabled, any object can be read without the need for a correct community string. By default the Control Password is webrelay. Xytronix Research & Design, Inc. page 97