Safe Mounting Distance
Detection Zone Approaches
Normal (Perpendicular) Approach
This figure displays the normal (perpendicular) approach to the detection zone:
S:
1:
2:
3:
4:
Minimum safe distance
Hazardous zone
Detection zone
Direction of approach
Fixed guard
If the operator’s direction of approach is perpendicular to the detection zone as shown in the figure and the
resolution of the system is 40 mm or less, use the following formula to calculate the safe mounting
distance, S:
S= (K x T) + C
S = (2000 mm/s x T) + 8 x (R – 14 mm), where:
K = 2000 mm/s
T = Total response time
C = 8 x (R – 14 mm), but not less than 0
R = Resolution of the light curtain in millimeters.
You can calculate the safe mounting distance S, using this formula with values for T and R that are
appropriate for the light curtains.
The following lists the conditions for safe mounting distance calculation:
If the calculated value of S is greater than or equal to 100 mm (3.94 in.) and less than or equal to
500 mm (19.68 in.), use the calculated value for the safe mounting distance.
 If the calculated value of S is less than 100 mm, use 100 mm as the safe mounting distance.
 If the calculated value of S is greater than 500 mm (19.68 in.), recalculate S with an alternate value for
K as shown in the given formula:
S = (1600 mm/s x T) + 8 x (R – 14 mm)
