Download SAFETY TEST REPORT

Transcript
EN 60065
Clause
Requirement – Test
3
GENERAL REQUIREMENTS
P
Safety class of the apparatus .................................: Class I
P
4
GENERAL CONDITIONS OF TESTS
P
4.1.4
Ventilation instructions require the use of the test
box
5
MARKING
P
Comprehensible and easily discernible
P
Permanent durability against water and petroleum
spirit
P
Identification, maker, model ....................................: Refer to marking label
P
Class II symbol if applicable
N
Rated supply voltage and symbol ..........................: 100-240V~
P
Frequency if safety dependant
P
5.1
Result - Remark
Verdict
Yes
P
50/60Hz
Rated current or power consumption .....................: Max 35W for model 19L****,
20L**** and 22L****,
Max 40W for model 23L****,
See appended Table 5.1
P
Earth terminal
Class I equipment
P
Hazardous live terminals
No such terminal
N
Supply output terminals (other than mains)
No such terminal
N
5.3
Use of triangle with exclamation mark
Such symbol is indicated on
circuit diagram for specific
components.
P
5.4
Instructions for use
User’s manual is provided in
English
P
5.4.1
Mains powered equipment not exposed to dripping Refer to user manual.
or splashing. Warning concerning objects filled
with liquid, etc.
P
Hazardous live terminals, instructions for wiring
Not applicable
N
Instructions for replacing lithium battery
No lithium battery
N
Instructions for modem if fitted
No any modem
N
5.2
5.4.2
Class I earth connection warning
P
Instructions for multimedia system connection
P
Special stability warning for fixed installation
N
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
All pole switch used.
P
Instructions for permanently connected equipment
Not a permanently connected
equipment.
N
Safety Test Report #: SHE-1007-10462-LVD
Prepared for Shenzhen KTC Technology Co., Ltd.
Prepared by EMC Compliance Management Group.
Page 5 of 48