Transcript
In order to comply with EU Directive 2002/96/EC on Waste Electrical and
Electronic Equipment (WEEE):
This product may contain material which could be hazardous to human health and the
environment. DO NOT DISPOSE of this product as unsorted municipal waste. This
product needs to be RECYCLED in accordance with local regulations, contact your
local authorities for more information. This product may be returnable to your
distributor for recycling - contact the distributor for details.
MONARCH INSTRUMENT
Instruction Manual
Para obedecer con EU Directiva 2002/96/EC en el Desecho el Equipo Eléctrico y
Electrónico (WEEE):
Este producto puede contener la materia que podría ser la salud humana perjudicial para y el
ambiente. NO se DESHAGA de este producto el desecho municipal como no clasificado. Estas
necesidades del producto para SER RECICLADAS de acuerdo con las regulaciones locales, contactan
su administración local para más información. Este producto puede ser retornable a su distribuidor
para reciclar - contacta el distribuidor para detalles.
Afin de respecter la directive européenne 2002/96/EC sur l’Equipement Electronique
et les Déchets Electriques :
Ce produit pourrait contenir des matières qui peuvent être dangereuses pour la santé de l’homme
et de l’environnement. Ne pas jetter ce produit dans un container municipal inapproprié. Ce
produit doit être recyclé en accord avec les arrêtés locaux; contacter les autorités locales pour
plus de renseignements. Ce produit peut être renvoyé au distributeur pour recyclage - Contacter
votre distributeur pour plus de details.
Um den Vorschriften der EU-Direktive 2002/96/EC bezueglich elektrischer und
elektronischer Abfallstoffe (WEEE) nachzukommen:
Dieses Produkt kann Materialien enthalten, welche gesundheitsgefaehrdend und umweltschädlich
sind. Dieses Produkt DARF NICHT wie unsortierter Hausmuell entsorgt werden. Dieses Produkt
muss gemaess den oertlichen Bestimmungen recycled werden, bitte kontaktieren Sie die lokalen
Behoerden fuer weitere Informationen. Sie koennen dieses Produkt zum Recycling an Ihren Haendler
zurueckgeben, bitte kontaktieren Sie den Haendler fuer weitere Details.
Monarch Fiberscopes
FSI and FSX models
MONARCH INSTRUMENT
Printed in the U.S.A.
Copyright 2005 Monarch Instrument, all rights reserved
1071-8319-110
15 Columbia Drive
Amherst, NH 03031 USA
Phone: 603-883-3390
Fax: 603-886-3300
www.monarchinstrument.com
e-mail: [email protected]
TABLE OF CONTENTS
FIBERSCOPE MODELS ......................................................................... 1
BASIC SPECIFICATIONS (All Models)..................................................... 1
FSI Models .............................................................................................. 1
Main Features ............................................................................................... 1
6.
Never use the scope near moving parts such as gears and fan blades or moving belts.
Eyepiece Focusing
The Eyepiece has been factory set to be in focus and should need very little adjustment in the
field. You should only need to turn the eyepiece by several turns in either direction to be in
focus. If you feel resistance in adjustment, do not exert force. Reverse direction. Continue until
the image is in focus.
Cleaning and Storage
1.
Always wipe the tip, shaft, and housing down with a soft clean cloth to remove
residue and moisture.
Batteries and Replacement .......................................................................... 2
Lighting ......................................................................................................... 2
2.
Use a proper cleaning liquid (diluted dishwashing soap) and rinse tip and shaft with
water. Dry.
FSI-XX-6-H Models ................................................................................... 2
3.
Batteries and Replacement .......................................................................... 2
Lighting ......................................................................................................... 3
Halogen Lamp Replacement ....................................................................... 3
When needed, gently clean the distal tip lens and eyepiece surfaces with a lens cleaner
such as isopropyl alcohol and a cotton tip swab.
4.
When needed, clean the condenser lens with a clean cotton tissue (FSX Models).
5.
The scope should be completely dry before storing in case.
FSI-XX-10-L Models ................................................................................. 2
FSX Models ............................................................................................. 3
Precautions
Main Features ............................................................................................... 3
Lighting and Attachment ............................................................................... 3
1.
The flexible shaft of the scope can be immersed into appropriate fluids for
short periods. Always clean and dry after use.
Accessories ............................................................................................ 4
2.
Never immerse handles into fluids. The handle assembly is splash resistant
and designed to prevent dust infiltration – NOT LIQUIDS.
Mirror ............................................................................................................. 4
Magnet ........................................................................................................... 4
General Operation, Checks, and Care of all Scopes ................................ 4
If any problems occur with your scope, do not attempt to open the scope housing. If you
encounter any problems, call Monarch as soon as possible for corrective action.
General Scope Checks before and after each use ...................................... 4
Operation ...................................................................................................... 4
Eyepiece Focusing ....................................................................................... 5
Cleaning and Storage ................................................................................... 5
Precautions ................................................................................................... 5
SAFEGUARDS AND PRECAUTIONS
Read and follow all instructions in this manual carefully, and retain this manual
for future reference.
Do not use this instrument in any manner inconsistent with these operating instructions
or under any conditions that exceed the environmental specifications stated.
These instruments are not user serviceable. For technical assistance, contact the
sales organization from which you purchased the product.
Monarch Instrument’s Limited Warranty applies. See www.monarchinstrument.com
for details.
Warranty Registration and Extended Warranty coverage available online at
www.monarchinstrument.com.
5
To attach the flashlight:
1.
Remove the 1.25” diameter standard
Condenser coupler from the case and
screw onto the connector fitting (See
Figure 3). Do Not Over tighten.
2.
Tip:
Congratulations on buying a high quality product from Monarch Instrument. We take pride in not
only selling our products but also serving and reacting to the needs of our present and future
customers.
The Fiberscopes from Monarch Instrument will pay for themselves over and over again in reduced
labor costs and virtually eliminating the guesswork when investigating so many inaccessible areas.
While holding the coupler firmly in
hand, push the head of the flashlight
into the coupler until seated.
FIBERSCOPE MODELS
This manual covers all the FSI and FSX Fiberscope models and variations. This manual is divided
into the FSI and FSX models and each model is addressed pertaining to the features including shaft
type, lighting, switching, and batteries.
The coupler has a Nitryl O-ring which
may need a thin film of silicone grease or
Vaseline from time to time. This will
facilitate the flashlight to slide in.
Figure 3 FSX Flashlight Attachment
Accessories
BASIC SPECIFICATIONS (All Models)
Viewing Angle:
40 degrees
45° Mirror
Viewing Distance: 0.4 inch [10.16 mm] to Infinity
The clip on mirror (5.8mm - P/N 7831-0953,
10mm - P/N 7831-0954) provides for viewing 90
degrees to the direction of the shaft.
Housing Material: Nylon 6
Bending Radius:
3 inches [7.62 cm] Minimum
Operating and Storage Temp: -40 °C [-104 °F] to 60 °C [140 °F]
Magnet
Tip Diameter:
The clip on magnet (5.8mm - P/N 7831-0955,
10mm - P/N 7831-0956) can pick up all ferrous metals
up to approximately ¼ lbs.
To attach the mirror or magnet: grasp the clip as shown
in Figure 4, tilt while aligning against flat of the distal
tip and push down into the recessed area.
10mm shaft: 0.41 inch
6mm shaft: 0.228 inch
FSI Models
Main Features
Figure 4 Mirror/Magnet
Attachment
General Operation, Checks, and Care of all Scopes
Housing
Eyepiece
General Scope Checks before and after each use
1.
Before and after each use, check scope for rips, tears, and abrasions.
2.
Check for proper operation of lighting. If dim or not lighting, first replace batteries.
3.
Check for smooth rotation of eyepiece.
General Operation
4
1.
Always exercise care when inserting and removing the shaft of the scope into and
from the hole of the object you are inspecting.
2.
Try to pre-determine the route and location of the area you are inspecting. With this
you can pre-bend the 10 mm shaft in the direction you require to facilitate viewing.
3.
Never bend the shaft length tighter than 3 inches [7.62 cm] diameter.
4.
Never expose the housing to water or liquids.
5.
Never insert the shaft into hot locations greater than 60 °C [140 °F].
On/Off
Switch
Distal
Tip
Battery
Door
Shaft
1
FSI-XX-10-L Models
Lighting
The FSI-XX-6-H models are equipped with a replaceable halogen lamp located just beneath the
battery door. See Figure 2.
Batteries and Replacement
The FSI-XX-10-L series are powered by
AA batteries (4). The batteries are held
within a removable battery pack just
beneath the battery door. See Figure 1.
The halogen lamp life is 15 - 20 hrs.
Halogen Lamp Replacement
In the event the lamp needs replacement:
To replace the batteries:
1.
Remove the battery door with a
Phillips screwdriver.
2.
Tilt battery pack up from the
bottom of handle and remove the
batteries from the battery pack.
Do not put unnecessary strain on
the wire leads and never pick up
the scope by the leads.
3.
Un-clip the connector if desired.
4.
Replace the batteries, reattach the
Figure 1 FSI-XX-10-L Battery Pack
connector and replace in reverse
order. Please make sure not to pinch any wires when closing the cover.
Lighting
The FSI-XX-10-L series are equipped with service free integrated solid-state LED lamps.
Simply, these lamps never need servicing for the life of the scope.
NOTE: Please refer to “ General Operation, Checks, and Care of all Scopes” section within this
manual for trouble free service.
1.
Remove the battery door with a Phillips screwdriver and set aside.
2.
Remove the battery pack and set aside.
3.
Using a small screwdriver, needle-nose pliers, or similar, tilt the lamp up out of the
base clip and remove.
4.
Replace with Monarch lamp P/N 7831-0957. Lay lamp body in clip and press down.
5.
Replace the battery pack and test for proper illumination by activating switch.
6.
Replace the battery door.
NOTE: Never touch the lamp body just after operation. The halogen lamp operates at a high
temperature and needs time to cool down.
FSX Models
Main Features
Housing
Eyepiece
FSI-XX-6-H Models
Condenser
Batteries and Replacement
Distal
Tip
The FSI-XX-6-H models are powered by a
DL-223 6V Lithium battery pack
(P/N 7831-0958) located just beneath the battery
door. See Figure 2.
Optional Flashlight
(P/N 7831-0951)
To replace the batteries:
1.
Remove the battery door with a Phillips
screwdriver.
2.
Tilt the battery pack up from the base
of the handle and pull the battery pack
out.
3.
2
Replace with a new battery pack in
reverse order.
Shaft
Figure 2 FSI-XX-6-H Battery Pack
and Halogen Lamp
Lighting and Attachment
The FSX models use an optional detachable flashlight for their illumination source.
Because the FSX scopes are rugged instruments but contain precision optical components,
never use the flashlight solely as a handle. Always keep hold of the FSX housing when in use.
3