Download MON2-3W MON2
Transcript
MON2-3W and MON2-3/6.8 User Manual P/N 821525 Rev-E Section 3: Technical Information CVBS (MAV-1) Input Option Field Upgrading This section explains the procedures for field upgrading your unit with additional composite video (CVBS) input module(s). 1) We advise you remove the MON2-3 from the mounting frame and work with the unit on a clean, well lighted work bench. 2) Ensure the MON2-3 is disconnected from the power mains. 3) Remove top cover. Retain screws for later reassembly. 4) Remove blanking plugs from slot where MAV-1 is to be installed. (Rear panel sections 2A and/or 3A) 5) Remove flat ribbon cable from rear I/O PC board. (Horizontal removal/insertion.). 6) Cut termination resistor from rear main board at the point labeled “B Input Cutout”. (Note: this is to allow HIZ/75 ohm termination selection from the MAV-1 board). 7) Install the flat ribbon connector supplied with the interface into the connector the ribbon was disconnected from in step #4. 8) Insert the flat ribbon into the rear (horizontal) flat ribbon connector labeled “J3” on the MAV-1 board. 9) Insert the flat ribbon cable to the front LCD into the inboard (vertical) flat ribbon connector labeled “J4” on the MAV-1 board. 10) Attach the MAV-1 to the rear panel using the supplied BNC nuts. 11) Double check all wiring and connections. 12) Connect CVBS signal and confirm operation. 13) Replace cover and return unit to service. Note: Each channel can accept only one additional input option; either an SDI (MSDI-4) input module or an additional CVBS (MAV-1) input module. © 2007 PANORAMAdtv ALL rights reserved 21