7. TOTAL PRODUCT CALCULATIONS USING WINDOW 7.4 Overall Product U-factor, SHGC, VT, and CR Calculations
6. Determine the Sightline Group Leader
The sightline group leader is the mid-point of each band:
Group leader = Areadaylight,largest – [(Group Leader Number - 0.5) * GABW)]
So, for example:
1st group leader = Areadaylight,largest – (0.5) * GABW)
2nd group leader = Areadaylight,largest – (1.5 * GABW)
3rd group leader = Areadaylight,largest – (2.5 * GABW)
And so forth for the number of GABW calculated.
7. Calculate SHGC and VT for each Sightline Group Leader
Model each group leader and use the SHGC0, SHGC1, VT0, and VT1 numbers to calculate the SHGC
and VT for each group.
THERM6.3/WINDOW6.3 NFRC Simulation Manual
June 2013
7-11