Download FW-3170 User`s Manual Part 1 (Product Overview)
Transcript
FW-3170 User’s Manual Part 1 FW-3170 User’s Manual Part 1 (Product Overview) Version 4.0 2009-3-19 Seyeon Tech Co., Ltd www.seyeon.co.kr www.flexwatch.com 4041-00 1 Seyeon Tech Co., Ltd FW-3170 User’s Manual Part 1 Contents 1. 2. 3. 4041-00 Product Overview ........................................................................................................................4 1.1. FW-3170 ..............................................................................................................................4 1.2. Key Functions of FW-3170 ..................................................................................................4 1.3. Technical Specification of FW-315 ......................................................................................5 1.4. FW-3170 Packing List..........................................................................................................7 Hardware Description ..................................................................................................................8 2.1. FW-3170 Front Panel View..................................................................................................8 2.2. FW-3170 Rear Panel View ..................................................................................................9 FW-3170 H/W installation and basic setup .................................................................................9 3.1. Before installation,................................................................................................................9 3.2. Factory Default Condition...................................................................................................10 3.3. FW-3170 H/W Installation..................................................................................................10 2 Seyeon Tech Co., Ltd FW-3170 User’s Manual Part 1 Notice • The materials in this document are for information use only and are subject to change without notice. While reasonable efforts have been made in the preparation of this document, to assure its accuracy, Seyeon Tech. assumes no liability resulting from errors or omissions in this document; or from the use of the information contained herein. • Seyeon Tech. reserves the rights to make changes in the product design without reservation and without notification to its users. Copyright Copyright 1999-2008 Seyeon Tech Co., Ltd. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent of Seyeon Tech Co., Ltd. Copyright 1999-2009 Seyeon Tech Co., Ltd. 810-12 Yeok Sam-dong, Kang Nam-gu, SEOUL, 135-081, TEL : 82 2 3017 0855 / KOREA FAX : 82 2 3017 0843 URL : http://www.flexwatch.com Warning To prevent risk of electric shock, do not remove the system-case. Any repair or modifications for the product will be allowed by qualified service personals only. Do not expose this appliance to water or moisture. Do not install this product in hazardous areas where highly combustible or explosive products are stored or used. Important Information • Before installation, please read and observe all instructions and warnings contained in this manual. Retain this manual with the original receipt for future reference and warranty. • If any items are missing from the package when you open the box, Please DO NOT install or OPERATE the FlexWATCH® server. Contact the local Dealer or Distributor. • Please record the following information for technical support and the track record in case of any theft or loss. Serial Number can be found on the underside of FlexWATCH® server. Warranty • 2 year Limited. • Product : Network Video Server • Model Name : FW-3170 • Serial Number : _00-30-6F- • Purchase Date : __________________ (yy/mm/dd) 4041-00 - - _ 3 Seyeon Tech Co., Ltd FW-3170 User’s Manual Part 1 1. Product Overview 1.1. FW-3170 FW-3170 server is 1ch Network Video Server, which transmits digital images captured by Analog CCD camera over the Internet. So users can view real-time live images over the Internet at anytime and anywhere using the standard web browser such as MS Internet Explorer or Netscape Communicator. There is no need other specific software to view real-time live images over the Internet. FW-3170 server is state-of-the art device and leads new generation of monitoring and security solution. Picture 1 : FW-3170 1.2. Key Functions of FW-3170 1. Standalone device built-in web server 2. Max 30 fps transmission speed on TCP/IP network 1. 10M/100M Auto Sensing Ethernet 2. Effective Bandwidth & Bit-rate Control by H.264 3. Built-in 2 way Audio transmission (1ch A-in, 1 A-out) 4. Supports Dynamic IP users by www.ipcctvdns.com and www.aoip.co.kr server 5. Supports Sensor Input, Digital Output 6. Supports Transparent mode 7. Encryption function by user authentication 8. Image transmission function via FTP, Email 9. Supports Various PTZ (Pan/Tilt/Zoom) Devices 10. 1CH V-out for displaying on analog monitor 4041-00 4 Seyeon Tech Co., Ltd FW-3170 User’s Manual Part 1 1.3. Technical Specification of FW-315 Model Name Hardware Video compression Resolution Frame rate (each channel) Video Streaming FW-3170 32bit Embedded CPU Flash 8Mbytes /SDRAM: 128Mbytes Linux version 2.6.14 operating system Battery backed up real-time clock Motion JPEG H.264 NTSC: 704x480,352x240,176x112 PAL: 704x576,352x288,176x144 Motion JPEG: Up to 30/25 fps at D1 (Secondary Stream at QCIF) H.264: Up to 30/25 fps at D1 (Secondary Stream at QCIF) Motion JPEG and H.264 Dual Streaming (Simultaneously) Controllable frame rate and bandwidth LAN interface Compression levels: 6 (Motion JPEG) / 6 (H.264) Color: color, black & white 8 bit PCM(G.711-u-low), Sampling rates 8KHz, Mono Audio 1ch in & 1ch out 10/100BaseT Ethernet auto sensing Alarm I/O Interface 1 Photo-coupled inputs and 1 Relay output Video Input 1 Channel Composite Video Input Video Output 1 loop through analog video outputs Two serial ports for console, modem(PSTN & GSM), serial input/output device, PTZ COM Port is RS-232, AUX port can be configured as RS-485 Max Baudrate: 115200 bit/s Multi user level protection for camera access, PTZ, Alarm I/O Up to 15.5M memory for Pre/Post alarm buffer e-mail, FTP, alarm Buffer by event or schedule IP notification, Alarm Notification to e-mail, CGI Call by event or schedule Accuracy: 12x12=144 blocks Motion Sensitivity : -100 ~ 100 : 100 is hypersensitive PTZ and UART device control through serial interface Up to 35 PTZ protocols from Pelco “ P” & “ D” protocol, Vicon V1311RB, Samsung, Honeywell and Etc., X10 device control Dial in/out via PSTN or GSM modem Transmit Serial input data transfer with Video IP notification by e-mail Configurable by serial, web or telnet Remote system update via telnet, FTP OR web browser. Provides HTTP CGI API ActiveX control development kit SMPS input: 100~240VAC, 300mA Output: DC 12 Volt, 800mA Image setting Audio Serial Interface Security features Advanced Service Built-in Motion detections PTZ & UART Control Support Others Management Developer support PWR Supply 4041-00 5 Seyeon Tech Co., Ltd FW-3170 User’s Manual Part 1 PWR Consumption Operating Environment Accessories Miscellaneous DC 12Volt 500 mA Temperature: 32° ~ 122°F (0° ~ 50°C) Humidity: 20 ~ 80% RH(non-condensing) Console cable for system set up Test LAN cable CD for User Guide, Installation wizard Quick Installation guide Freely downloadable NDVR Software AVI conversion tool support by FW-voyager. Work with FW-Manager( NDVR S/W) Dynamic IP support through AOIP Users 16 simultaneous users Installation, management and maintenance Installation CD and web-based configuration Firmware upgrades over HTTP or FTP , firmware available at www.flexwatch.com Video access from Web browser Video access from Web browser Minimum Web browsing requirements System integration support Supported protocols Applications Approvals Dimensions (HxWxD) and weight 4041-00 Pentium III CPU 500 MHz or higher Windows XP, 2000, NT4.0*, Internet Explorer 6.x or later Powerful API for software integration available at http://www.flexwatch.com, including Simple Viewer API, FlexWATCH Control SDK, event trigger data in video stream, embedded scripting and access to serial port peripherals over HTTP/TCP User can be installed user program daemon for event notification or sending image. Embedded operating system: Linux 2.6 HTTP, TCP/IP, FTP, Telnet, RARP, PPP, PAP, CHAP, DHCP, SMTP client(e- mail), NTP, Java, RTP/RTSP, UPnP FlexWATCH Manager 16/32/128/256 (not included) FCC : Class A CE : Class A RoHS Size :110 mm(L) x 84 mm(W)X 35 mm(H) 4.3 ”(L) x 3.3 ”(W)X 1.37”(H) Weight : 310 g (0.47 lbs) without power supply. Table 1 : FW-3170 Specification 6 Seyeon Tech Co., Ltd FW-3170 User’s Manual Part 1 1.4. FW-3170 Packing List FW-3170’s packing box includes the following items. FW-3170 1ea Power Supply Unit (Power Cable & SMPS DC12V 0.8A Adapter) 1ea Direct Cable 1ea CD (User’s Manual, Installation wizard, Picture, etc) 1ea Table 2 : FW-3170 Packing List F Please check all the listed items are included in your package. For any missing items, please contact your local distributor. 4041-00 7 Seyeon Tech Co., Ltd FW-3170 User’s Manual Part 1 2. Hardware Description 2.1. FW-3170 Front Panel View Picture 2 : FW-3170 Front Panel A B C D E Name A Power B Grounding Connector C Factory Default Button D LAN E COM F POWER LED (RED/GREEN) G LAN(Tx/Rx) LED (RED/GREEN) 4041-00 F G Description Power input ports for DC 12V 0.8A [SMPS]. Ensure to use the original power supply unit from the package. Grounding Connector This button can reset the factory default settings at the system. Especially when a user lost his/her admin-password, or when it got any uncertain faulty operation. - After reboot the system, wait until hearing two times of beep sound. - Keep pressing FD button for 5~10 seconds until hearing three times short beep sound. ACT LED blinks during the process. The system will reboot automatically when it’s completed. LAN Port for 10/100M Base T Auto sensing. RS-232 ports for Serial input device, Modem or Console (HyperTerminal connection). RED light – It blinks RED when power on. GREEN light – It blinks GREEN when IP setup is done. RED light – It blinks RED when data is being transmitted on the connected LAN port GREEN light – It blinks GREEN only when LAN port is connected without data transmission. Table 3 : FW-3170 Front Panel Description 8 Seyeon Tech Co., Ltd FW-3170 User’s Manual Part 1 2.2. FW-3170 Rear Panel View Picture 3 : FW-3150 Rear Panel View A B C Name D E F Description A Video In BNC cable port for 1ch Video input. B Video Out 1ch Video Output port displaying on Analog Monitor. C MIC, SPK 1ch Audio Output and Input D RS485 RS-485 Ports for PTZ E DI (SENSOR) Signal input ports for sensor and contact. F DO (ALARM) Signal output ports for alarm and light. Table 4 : FW-3170 Rear Panel Description 3. FW-3170 H/W installation and basic setup 3.1. Before installation, 1. Read carefully User’s Manual 2. Check-out if the power source is stable or not at the environment. 4041-00 9 Seyeon Tech Co., Ltd FW-3170 User’s Manual Part 1 3.2. Factory Default Condition The following table shows the factory default condition. Please refer to this when you need to change the values on admin menu. Factory Default Condition Admin ID root Admin password root IP address 10.20.30.40 Network mask 255.255.255.0 Gateway 10.20.30.1 Table 5 : Factory Default Condition F Factory default Admin ID and Password are all lower case letters. You can change the password with Capital letters. 3.3. FW-3170 H/W Installation Following steps show the physical installation process for FW-3170. 1. Install CCTV cameras at each required position. 2. Connect BNC cable between CCTV camera’s V-out and FW-3170’s V-in. 3. Connect a LAN cable at FW-3170 in your local network. 4. Connect the power cable at FW-3170. After that, you need to follow the steps below. 5. First, Network Configuration by FW-installer. 6. Second, Camera Configuration by FW-installer or admin-menu. 7. Third, Service Configuration by FW-installer or admin-menu. F For IP setup, refer to “Chapter 2.Network Configuration” on User’s Manual Part2. 4041-00 10 Seyeon Tech Co., Ltd