invoking the Swap G2 & G1 checkbox. When unchecked (the default condition) the G1
symbol is followed by the G2 symbol. When enabled the symbols are sent in reverse
order (G2 followed by G1).
4.6.2.5.3 Invert G2 Checkbox
The user may independently invert the logic sense of the G2 symbols by checking the
Invert G2 checkbox.
4.6.2.5.4 Invert Data Checkbox
The user may invert the logic sense of both the G1 and G2 symbols by checking the
Invert Data checkbox.
4.6.2.5.5 Falling Clock Edge Checkbox
The user has control of the timing relationships between the output data (I & Q) and
output clocks (I & Q) by invoking the Falling Clock Polarity command. When
unchecked, the start of each data bit will occur with the Rising edge of the clock. When
enabled, the start of each data bit will occur with the Falling edge of the clock.