ioNODE 24/24
Note that each bank has its own feedback of a fault condition. Thus an overheated output
will shut down all the outputs in the same bank but will not affect the other banks. An
overloaded output can be traced to its bank of eight. Each bank has its own error reset
line which may be used to clear the fault in any output on that bank, all of the outputs will
be momentarily disabled while the fault is being cleared.
The output connections are summarised below:
pin
J30
J31
J33
1
2
3
4
5
6
7
8
9
10
Dout0
Dout1
Dout2
Dout3
Dout4
Dout5
Dout6
Dout7
usrV+0
usrgnd0
Dout8
Dout9
Dout10
Dout11
Dout12
Dout13
Dout14
Dout15
usrV+1
usrgnd1
Dout16
Dout17
Dout18
Dout19
Dout20
Dout21
Dout22
Dout23
usrV+2
usrgnd2
A green LED, D8, flashes every time a change of output command has been received. The
outputs may be operated from 12V to 24V. Operation above 30V may cause damage.
As with the other CAN Peripherals, the isolation provided is nominal, Dout0–23,
usrV+0–2 and usrgnd0–2 must all be within 42.4V of the machine’s safety earth
(ground) potential.