Download Manual
Transcript
5. Configure the data filter conditions that will be applied for the „Delete data‟ job. If you do not set any data filter conditions, than all events older than the specified period will be deleted. Click Next to continue. NOTE: For more information on how to configure filter conditions, refer to the section „Configuring data filter conditions„ in this chapter. 6. Specify whether the maintenance job should be scheduled or executed immediately. 7. Click on Finish to finalize configuration of the new „Delete data‟ job. 12.9 Configuring data filter conditions Use data filter conditions to specify which events will be affected by the maintenance job. Only events which match the specified criteria will be processed, moved, exported, deleted or imported. Filters can be created for all log types supported by GFI EventsManager. Screenshot 144 - Data filter dialog To specify which events are affected by maintenance jobs, click on the Filter button in the data filter dialog. This dialog is available through the „New job wizard‟. Example: Windows Event Log filter Export events from the Windows Event Log with the following conditions: Log type: Security Event ID: 540 - Successful logon User: administrator GFI EventsManager user manual Database Operations 139