Download LabVIEW Control Design Toolkit User Manual
Transcript
Chapter 4 Connecting Models Figure 4-9 uses the block diagram from Figure 4-5 but replaces the Tanks input with Ht. As in Figure 4-5, the two valves are connected in series with each other. In Figure 4-9, however, the two tanks now are appended to each other. Figure 4-9. Appending the Two Tanks Connecting Models in Parallel A parallel connection creates a single model from two separate systems that share common inputs. You also can use a parallel connection to add or subtract outputs of two subsystems and represent them as a single output. Use the CD Parallel VI to connect systems in parallel. For example, consider the circuit system in Figure 4-10. i i1 R1 i2 R2 v L1 L2 Figure 4-10. Circuit System Control Design Toolkit User Manual 4-8 ni.com