9.4
Replacing PWA,
Continued
Procedure, continued
Table 55
Replacing PWA, continued
Step
4
5
Action
If your transmitter…
has Local Smart Meter
Option
does not have Local Smart
Meter Option
Then…
go to Step 5
go to Step 7
Note orientation of mounting bracket on PWA (side without cable
connectors). Unplug meter cable from connector on PWA. Remove
screw retainers from other side of mounting screws so you can
remove screws and mounting bracket from PWA. Set PWA aside.
Mounting Screws
PWA Connector Side
REV
Meter cable is installed
between PWA and
mounting bracket.
X
1
XXXXXX ASSY XXXXXXXX-XXX
W
R
W
Meter Cable
6
Restraining
Clip
Mounting
Bracket
J4 Meter
Connector
Orient mounting bracket as noted above with meter cable still located
in slot on its right-hand side, install mounting screws through bracket
and replacement PWA, and install retainers to hold screws in place.
Plug meter cable into connector J4 on PWA and be sure cable is still
under restraining clip on front of bracket. Go to Step 9.
Continued on next page
176
ST 3000 Release 300 and SFC Model STS103 User’s Manual
7/00