Download Draft
Transcript
Draft Operation and Features 3.4.2.3 Guidelines When Using Free-run When using free-run mode to control exposure, several general guidelines must be followed: • The line period must not be lower than the minimums shown in Table 3-4. Video Data Output Mode L401k Single tap (no two-line averaging) 141.733 µs 141.86 µs Dual tap (no two-line averaging) - 70.93 µs Dual separated tap (no two-line averaging) - 70.93 µs 283.466 µs 141.86 µs Dual tap (with two-line averaging) - 141.86 µs Dual separated tap (with two-line averaging) - 141.86 µs Single tap (with two-line averaging) L402k Table 3-4: Minimum Line Periods • In the free-run programmable mode, the minimum exposure time and the maximum exposure time must be within the limits specified in the Exposure Time CSR (see page 4-14). L We strongly recommend using an exposure time that is at least 10% of the line period. Exposure times shorter than 10% of the line period will increase the non-linearity of the camera’s response. • When you are operating the camera in free-run, using the edge-controlled mode will give you the best performance in terms of signal-to-noise ratio. 3.5 Integrate Enabled Signal An output signal called Integrate Enabled (IntEn) is available on L400k cameras. The integrate enabled signal indicates that an exposure is taking place. The signal will go high when each exposure begins and go low when the exposure ends. The characteristics of the signal are described in more detail in Section 2.5.6. 3-10 Basler L400k