Transcript
The gain of the receiving amplifier increases as a function of time (Figure 5-6) to compensate for signal losses at further distances and decreases its bandwidth to reduce noise pick-up. When a signal is received by the system, a current source is turned on if the signal is above a preset threshold level. The current source charges a capacitor until the voltage on the capacitor reaches 1.2 Volts. The system generates a logic level output signal at the time of the received echo. The time interval between the transmit signal start ( Internal CLK or Ext. Trigger Input) and the received echo (ECHO Output) can then be measured, multiplying this time by the speed of sound yields the round trip distance to the object. If the actual distance is not required, a simpler timing circuit can be employed to determine when an object comes within some preset zone of the sensor. FIGURE 5-6 Note: ONLY the graphs of the first eight gain steps are included here for clarity. Step 9-11 are identical to step 8 except that each successive step is increased in gain by 4 dB. These graphs are generated from theoretical information, not experimental data. FIGURE 5-5 22 23