Download IQ 310 System Manual

Transcript
IQ 310 System Manual
Section 5, DLP-6
During the TFTP upload process, various status messages display in CURRENT UPDATE STATUS to
indicate progress. The following table describes these messages.
Message
Meaning
TFTP UPLOAD IN
PROGRESS
Indicates communication with the TFTP network server has been
established and the update file is being transferred between the IQ 310 and
the TFTP network server.
MODULE
UPDATE IN
PROGRESS
The IQ 310 is now writing the code file into the flash (RAM to ROM).
MODULE
UPDATE
COMPLETE
Indicates the IQ 310 successfully received the update file.
TFTP ERROR:
TIMEOUT
This message will appear if the TFTP server IP address is incorrect.
TFTP ERROR:
Indicates the TFTP network server was unable to locate the specified
FILE NOT FOUND filename or path in the TFTP Server Filename field. Filename may be
incorrect.
9. When the update process has successfully completed, MODULE UPDATE COMPLETE displays in the
CURRENT STATUS field.
The IQ 310 will restart immediately and resume operation. The user may then Telnet back into the
unit.
Follow-up Procedures
Once this procedure is complete, return to the procedure which referred you to this DLP and continue with
the tasks indicated there.
61203800L1-1A
© 2004 ADTRAN, Inc.
101