Download ~ tilliJ - Amazon Web Services
Transcript
eotec Lock the Muii1Sensor ma1n unll to liS battery~v·er by allg111ng the Lock/Unlock Half· D1mpte Markers un r the "unlOCk" symbol and tw1st1ng the battery cover from t e ma1n unll In a clockwise motion unlit the Lock/Unlock Hal D1mpte Markers form a c~rcle under tho "lOCk" symbol (a tan ble chck Will be felt). This product !ses radio to wirelessly communicate data betwee itself and other devices. Radio communicatio is inherently not always 100% reliable, and f s such, this product should not be used in situat ns in which life and/or valuables are solely depend nt on its funct1on. Harmonizing the Digital Home (_ ) echnical Specs · MultiSonsor Physical Installation Instructions: Th~re tuo 2 methods to physically mount the MulbSensor on the wall or cOiling It can be mounted fiat against the wall via the B~tk · MOUrll Plato or angled In a direction v1a the Back-Mount Arm tmportont The MulhSensor is weathenzed and can operate outdoors 1n ra1n and snow Placed ou tdoors where directly exposed to ra1n and snow. the MulhSensor should be oriented such that the TemporJture/HumodliY Sensor is facing downward and positioned on tho bottom of the uM. (See the Weatherization Orientation SOCIIOn) Mounting the Mult1Sensor flat against the wall via the Back-Mount Plate. @ · Motion Sensor Effective Range: ® MultiSensor (Z-Wave 4-in-1 Sensor: Motion, Temperature, Humidity, and Light Sensor) Mounting tho MultiSensor angled in a direction via the Back-Mount Anm 3 motors ~ Ground ~ -@ Friel"" Lock The Aeotec MultiSensor is a USB or battery-powered Z-Wave motion sensor, temperature sensor, humidity sensor, and lighting sensor all in one package. The sensor will send radio signals to up to 6 associated Z-Wave devices within its own Z-Wave network when the Motion Sensor detects IR changes in front of its viewing window. Indoor/Outdoor functional tolerances allow the Aeotec MultiSensor to function under weatherized conditions. Various sensitivity levels can be configured to avoid unintentional triggering from small animals such as cats and dogs. By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via intermediary "listening· Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices. ~~ 10 meters €) ~ Note. The Back-Mount Anm may be locked in vanous angles by turning the Fnct1on Lock clockwise and cou nte r-clockwise to tighten or loosen (respectively) the angle of the arm. · MultiSensor Pl ter Instruction s: The Aeotec MulliS nsor has butlt in battery level detection. II w11l automatically repo its battery level to the associated gateway throughout its life until the battery is fully drained and needs replacing. The ba ry status will often be displayed in the user interface of the galvay. · Adjusting the Sensitivity on the MuttiSensor When used properl1 in an optimized Z-Wave network, operation via battery can functiool for 12 months before battery replacement. Tum the Sensitivity Knob in a clockwise direct1on to increase sensitivity and counter~dockwise to decrease sensitivity. Sensor from it's battery cover by twisting the m the main unit in a counter-ckxkwise motton •attery cover outward to separate the main unit · Weatherization Orientation: Package Contents: ~@@ 1) Multi Sensor 2) Back-Mount Ptate 3) Back-Mount Arm 4) AAA Batteries (x4) 5) USB Cable 6) Screws (x2) Unlocked ii ~ tilliJ Insert 4 AAAiatteries oriented according to t e picture located in the bane holder (with the negative end depressing the battery spring I J'tJJ ,I ~ CORRECT AEON LABS eotee Removing/R esetting the MultiSensor from your Z-Wave N etwork Press the button labeled "Remove" on the Aeotec Minimote to begin the Z-Wave removal process. Ha rmonizing the Digital Ho me The Aeotec Mui!ISensor must be paired (Included) into a Z-Wave netwoo before it can send Basic Set Command, Temperature, Hum1dity, and Light level reports to assoctatton group 1, wh1ch is setup via the Association Command dass. The Mult1Sensor can only communicate to dev1ce:S Within Its own Z -Wave network. Troubleshooting : If the MultiSensor was successf ully removed from the Z-Wave IIBiwork, pressing the Z-Wave Button will cause the LED to blink. If the MulliSensor was not successfully removed from lhe Z-Wave network the LED will stay sohd for a few seconds Press the bulton labeled "Include" on the Aeotec Minimote to begin the Z-Wave inclusion process Include The MultiSensor cal send Basic Set Command to assooation group 1, which is setup via the Association Command Class. when the Mo tion Sensor detects mo\'ement to control the associated dev1ces to ·oPEN'" state. After 4 minutJs by default. 1f the Mo t1on Sensor 1s no t triggered aga~n, the MultiSen sor will send Basic Set Command to these dev1ces to set them to their "CLOSE" stale. However, 1f the Motion SensO< IS tnggered again 10 4 m1nutes. the MultiSensor will reset the timing and start liming aga1n The 4 minutes dela) t1me can be changed through the usage of Z-Wave command built 1nto Z-Wave certified controllers/gateways . (The specific Z -Wave command supporting th1s function is Conftguration Command Class) Please con·Jult the operation manual for these controllers I gateways for speciftc 1nstruct1ons on setting the MultiSensor. Monitoring T~mperature, Humidity and luminance roubleshooting: If the MultiSensor was not successfully paired any Z-Wave network, the MultiSensor's LED Will blink when ressing the Z-Wave Button. If the MultiSensor was successfully aired into a Z-Wave netwO<k, the LED will stay solid for a few 3:conds when pressing the Z-Wave Button. 110 Aeon Labs warrants to the original purchaser o f Products that for the Warranty Penod (as defined below), the Products will be free from material defects in materials and workmanship. The foregoing warranty is subject to the proper Installation, operation end maintenance of the Products 1n accordance with installation instru9tions and the operating manual supplied to Customer. Warranty cJatms must be made by Customer 10 writing with1n th1rty (30) days of the mantfestat10n of a problem. Aeon Labs' sole obligatK>n under the foregoing warranty is, at Aeon Labs' opllon, to repair, replace or correct any such defect that was present at the t1me of delivery, or to remove the Products and to refund the purchase price to Customer. The MultiSensor Ci;ln report temperature, humidity, and luminance to a Z-Wave gateway Of controller when requested. If this function IS supported by the g .Jteway/ conlroller, the data will be displayed in the user interface of the gateway/ controller. (The specific Z-Wave command support.ng the monitoring is the Multilevel Sensor Command Class and Multi Channel Command Class. Automatic reports are sent til association group 1 , which is setup via the Association Comm1nd Class.) Please consult the operation manual for these gateways controllers for specific instructions on setting the Multi Sen sO<. THE INDEMNITY AND WARRANTY IN ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER INDEMNITIES OR WARRANTIES. WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE FCC NOTICE (for USA): THE MANUFACTURER IS NOT RESPONSIBLE FOR A NY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER'S AUTHORITY TO OPERATE THE EQUIPMENT. The ·warranty Penod• begins on the date the P'oducts IS delivered and cont1nues for 12 months STORE INDOORS WHEN NOT IN USE. SUITABLE FOR DRY LOCATIONS. DO NOT IMMERSE IN WATER NOT FOR USE WHERE DIRECTLY EXPOSED TO WATER Any repa1rs under this warranty must be conducted by an authorized Aeon Labs service representatwe and under .Aeon Labs' RMA pohcy. Any repairs conducted by unauthonzed persons shall void this warranty This dev1ce complies w1th Part 15 of the FCC Rules. OperatiOn 1s subJect to the following two condtt1ons Excluded from the warranty are problems due to accidents, acts of God. eMf or military authority. civil disturbance, war, strikes, fires, other catastrophes, m1suse, m1sapphcation, storage damage, negligence, electncal power problems, or mocMicallon to the Products or its components. Aeon Labs does not authorize any person or party to assume or create for it any other obligation or hab1hty '" connection with the Products except as set forth here1n. Aeon Labs will pass on to Customer all manufacturers' Material warranties to the extent that they are transferable, but will not Independently warrant any Matenal Monitoring M o tion Press the Z-Wave Sulton under the Battery Cover to begin the Z-Wave pairing process. ' Remove Note: The LED on the MulhSensor Will bhnk 1f it IS currently not paired 1nlo a Z-Wave network when pressing the Z-Wave Bullon Adding/Including/Pairing the MultiSensor into a Z-Wave Network Warranty Customer must prepay sh1pping and transportatbn charges for returned Products. and 1nsure the shipment or accept the nsk of loss or damage during such !:>hipmont and transportation. Aeun Labs wilt ship the repaired or replacement products to Customer freight prepaid. Customer shall 1ndemmfy, defend, and hold Aeon Labs and Aeon Labs' affiliates, shareholders, directors. officers. employees, contractors, agents and other representatwes harmless from all demands, cla1ms, actions. causes of action, proceed1ngs, su1ts, assessments, losses, damages, liabilities, settlemen ts, judgments. f.nes, penalt1es, 1nterest, costs and expenses (includ1ng fees and disbursements of counsel) or every kind (1) based upon personal injury or death or tnjury to property to the extent any of the foregoing is prox1mately caused either by a defective product (including strict liability in tort) or by the negligent or willful acts or om1ssions of Customer or 1Ui officers, employees. subcon tractors or agents, and/or (ii) arising from or relating to any actual or alleged infringement or m1sappropnat1on of any patent, trademark, mask work , copynght, trade secret or any actual o r alleged violation of any other intellectual property rights ansing from or in connect1on w1th the products, except to the extent that such tnfnngement ex1sts as a result of Aeon Labs' manufacturing processes. IN NO EVENT SHALL AEON LABS BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE. SPECIAL OR CONSEQUENTIAL DAMAGES. OR DAMAGES FOR LOSS OF PROFITS, REVENUE, OR USE INCURRED BY CUSTOMER OR ANY THIRD PARTY, W HETHER IN AN ACTION IN CONTRACT, OR TORT, OR OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. AEON LABS' LIABILITY AND CUSTOMER'S EXCLUSIVE REMEDY FOR ANY CAUSE OF ACTION ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF THE PRODUCTS, WHETHER BASED ON NEGLIGENCE, STRICT LIABILITY, BREACH OF WARRANTY, BREACH OF AGREEMENT, OR EQUITABLE PRINCIPLES. IS EXPRESSLY LIMITED TO, AT AEOTEC'S OPTION, REPLACEMENT OF, OR REPAYMENT OF THE PURCHASE PRICE FOR THAT PORTION OF PRODUCTS WITH RESPECT TO WHICH DAMAGES ARE CLAIMED. ALL CLAIMS OF ANY KIND ARISING IN CONNECTION WITH THI S AGREEMENT OR THE SALE OR USE OF PRODUCTS SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING WI THIN THIRTY (30) DAYS FROM AEON LABS' DELIVERY, OR THE DATE FIXED FOR DELIVERY IN THE EVENT OF NONDELIVERY. 1 This device may not cause harmful interference. and 2.This dev1ce must accept any Interference rece1ved, 1ncluding interference that may cause undesired operat1on. This eqUipment has been tested and found to comply w1th the hm1ts for a Class B digital device, pursuant to part 15 of the FCC Rules. These lim1ts are designed to provide reasonable protection against harmful interference In a restdenllal installation. This equipment generates, uses and can radiate rad10 frequency energy and. if not 1nstalled and used 10 accordance w1th the instructions, may cause harmful intorforonco to radio communications. However. there IS no guarantee that interference will not occur 1n a part1cular installation. If th1s eqUipment does cause harmful interference to rad10 or teleVISIOn reception, which can be determ~ned by turn1ng the equ1pment off and on. the user IS encouraged to try to correct the interference by one or more of the followmg measures· aReonent or relocate the receiVIng antenna alncrease the separation between the eqUipment and receiver •Connect the eqUipment into an outlet on a circuit d1tferent from that to wh1ch the receiver is connected •Consult the dealer or an expenenced radiO/TV techniCian for help. Warning: Do not dispose or electncal appliances as unsorted mun1cipal waste. use separate collect1on faciht1es. Contact your local govemment for 1nforma11on regarding the collection systems available Certifications (regional): Do not dispose of electrical appliances as unsorted mume~pal waste, use separate collection facilities. Contact your local government for mformatJon regarding the collection systems available. CE e Cfe www.aeon-labs.com www.aeotec.com AEON LABS