Download ~ tilliJ - Amazon Web Services

Transcript
eotec
Lock the Muii1Sensor ma1n unll to liS battery~v·er by allg111ng
the Lock/Unlock Half· D1mpte Markers un r the "unlOCk"
symbol and tw1st1ng the battery cover from t e ma1n unll In a
clockwise motion unlit the Lock/Unlock Hal D1mpte Markers
form a c~rcle under tho "lOCk" symbol (a tan ble chck Will be
felt).
This product !ses radio to wirelessly communicate
data betwee itself and other devices. Radio
communicatio is inherently not always 100%
reliable, and f s such, this product should not be
used in situat ns in which life and/or valuables are
solely depend nt on its funct1on.
Harmonizing the Digital Home
(_
)
echnical Specs
· MultiSonsor Physical Installation Instructions:
Th~re
tuo 2 methods to physically mount the MulbSensor on the
wall or cOiling It can be mounted fiat against the wall via the
B~tk · MOUrll Plato or angled In a direction v1a the Back-Mount Arm
tmportont The MulhSensor is weathenzed and can operate
outdoors 1n ra1n and snow Placed ou tdoors where directly exposed
to ra1n and snow. the MulhSensor should be oriented such that the
TemporJture/HumodliY Sensor is facing downward and positioned
on tho bottom of the uM. (See the Weatherization Orientation
SOCIIOn)
Mounting the Mult1Sensor flat against the wall via the
Back-Mount Plate.
@
· Motion Sensor Effective Range:
®
MultiSensor
(Z-Wave 4-in-1 Sensor:
Motion, Temperature, Humidity, and Light Sensor)
Mounting tho MultiSensor angled in a direction via the
Back-Mount Anm
3 motors
~
Ground
~
-@
Friel"" Lock
The Aeotec MultiSensor is a USB or battery-powered
Z-Wave motion sensor, temperature sensor, humidity
sensor, and lighting sensor all in one package. The
sensor will send radio signals to up to 6 associated
Z-Wave devices within its own Z-Wave network when
the Motion Sensor detects IR changes in front of its
viewing window.
Indoor/Outdoor functional tolerances allow the Aeotec
MultiSensor to function under weatherized conditions.
Various sensitivity levels can be configured to avoid
unintentional triggering from small animals such as cats
and dogs.
By taking advantage of the Z-Wave mesh network,
commands can be routed to their destination via
intermediary "listening· Z-Wave products. Products that
are Z-Wave certified can be used and communicate with
other Z-Wave certified devices.
~~
10 meters
€) ~
Note. The Back-Mount Anm may be locked in vanous angles by
turning the Fnct1on Lock clockwise and cou nte r-clockwise to
tighten or loosen (respectively) the angle of the arm.
· MultiSensor Pl ter Instruction s:
The Aeotec MulliS nsor has butlt in battery level detection. II w11l
automatically repo its battery level to the associated gateway
throughout its life until the battery is fully drained and needs
replacing. The ba ry status will often be displayed in the user
interface of the galvay.
· Adjusting the Sensitivity on the MuttiSensor
When used properl1 in an optimized Z-Wave network, operation via
battery can functiool for 12 months before battery replacement.
Tum the Sensitivity Knob in a clockwise direct1on to increase
sensitivity and counter~dockwise to decrease sensitivity.
Sensor from it's battery cover by twisting the
m the main unit in a counter-ckxkwise motton
•attery cover outward to separate the main unit
· Weatherization Orientation:
Package Contents:
~@@
1) Multi Sensor
2) Back-Mount Ptate
3) Back-Mount Arm
4) AAA Batteries (x4)
5) USB Cable
6) Screws (x2)
Unlocked
ii
~ tilliJ
Insert 4 AAAiatteries oriented
according to t e picture located
in the bane holder (with the
negative end depressing the
battery spring
I
J'tJJ ,I
~
CORRECT
AEON LABS
eotee
Removing/R esetting the MultiSensor from your
Z-Wave N etwork
Press the button labeled "Remove" on
the Aeotec Minimote to begin the
Z-Wave removal process.
Ha rmonizing the Digital Ho me
The Aeotec Mui!ISensor must be paired (Included) into a
Z-Wave netwoo before it can send Basic Set Command,
Temperature, Hum1dity, and Light level reports to
assoctatton group 1, wh1ch is setup via the Association
Command dass. The Mult1Sensor can only communicate
to dev1ce:S Within Its own Z -Wave network.
Troubleshooting : If the MultiSensor was successf ully removed
from the Z-Wave IIBiwork, pressing the Z-Wave Button will cause the
LED to blink. If the MulliSensor was not successfully removed from
lhe Z-Wave network the LED will stay sohd for a few seconds
Press the bulton labeled "Include" on
the Aeotec Minimote to begin the
Z-Wave inclusion process
Include
The MultiSensor cal send Basic Set Command to assooation group 1,
which is setup via the Association Command Class. when the Mo tion
Sensor detects mo\'ement to control the associated dev1ces to ·oPEN'"
state. After 4 minutJs by default. 1f the Mo t1on Sensor 1s no t triggered
aga~n, the MultiSen sor will send Basic Set Command to these dev1ces to
set them to their "CLOSE" stale. However, 1f the Motion SensO< IS
tnggered again 10 4 m1nutes. the MultiSensor will reset the timing and
start liming aga1n
The 4 minutes dela) t1me can be changed through the usage of Z-Wave
command built 1nto Z-Wave certified controllers/gateways . (The specific
Z -Wave command supporting th1s function is Conftguration Command
Class) Please con·Jult the operation manual for these controllers I
gateways for speciftc 1nstruct1ons on setting the MultiSensor.
Monitoring T~mperature, Humidity and luminance
roubleshooting: If the MultiSensor was not successfully paired
any Z-Wave network, the MultiSensor's LED Will blink when
ressing the Z-Wave Button. If the MultiSensor was successfully
aired into a Z-Wave netwO<k, the LED will stay solid for a few
3:conds when pressing the Z-Wave Button.
110
Aeon Labs warrants to the original purchaser o f Products that for the
Warranty Penod (as defined below), the Products will be free from
material defects in materials and workmanship. The foregoing warranty
is subject to the proper Installation, operation end maintenance of the
Products 1n accordance with installation instru9tions and the operating
manual supplied to Customer. Warranty cJatms must be made by
Customer 10 writing with1n th1rty (30) days of the mantfestat10n of a
problem. Aeon Labs' sole obligatK>n under the foregoing warranty is, at
Aeon Labs' opllon, to repair, replace or correct any such defect that was
present at the t1me of delivery, or to remove the Products and to refund
the purchase price to Customer.
The MultiSensor Ci;ln report temperature, humidity, and luminance to
a Z-Wave gateway Of controller when requested. If this function IS
supported by the g .Jteway/ conlroller, the data will be displayed in the
user interface of the gateway/ controller. (The specific Z-Wave
command support.ng the monitoring is the Multilevel Sensor
Command Class and Multi Channel Command Class. Automatic
reports are sent til association group 1 , which is setup via the
Association Comm1nd Class.) Please consult the operation manual
for these gateways controllers for specific instructions on setting the
Multi Sen sO<.
THE INDEMNITY AND WARRANTY IN ABOVE ARE EXCLUSIVE AND
IN LIEU OF ALL OTHER INDEMNITIES OR WARRANTIES. WHETHER
EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE
FCC NOTICE (for USA):
THE MANUFACTURER IS NOT RESPONSIBLE FOR A NY RADIO OR
TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS
TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE
USER'S AUTHORITY TO OPERATE THE EQUIPMENT.
The ·warranty Penod• begins on the date the P'oducts IS delivered and
cont1nues for 12 months
STORE INDOORS WHEN NOT IN USE. SUITABLE FOR DRY
LOCATIONS. DO NOT IMMERSE IN WATER NOT FOR USE WHERE
DIRECTLY EXPOSED TO WATER
Any repa1rs under this warranty must be conducted by an authorized
Aeon Labs service representatwe and under .Aeon Labs' RMA pohcy.
Any repairs conducted by unauthonzed persons shall void this warranty
This dev1ce complies w1th Part 15 of the FCC Rules. OperatiOn 1s subJect
to the following two condtt1ons
Excluded from the warranty are problems due to accidents, acts of God.
eMf or military authority. civil disturbance, war, strikes, fires, other
catastrophes, m1suse, m1sapphcation, storage damage, negligence,
electncal power problems, or mocMicallon to the Products or its
components.
Aeon Labs does not authorize any person or party to assume or create
for it any other obligation or hab1hty '" connection with the Products
except as set forth here1n.
Aeon Labs will pass on to Customer all manufacturers' Material
warranties to the extent that they are transferable, but will not
Independently warrant any Matenal
Monitoring M o tion
Press the Z-Wave Sulton under the Battery Cover to begin the
Z-Wave pairing process.
'
Remove
Note: The LED on the MulhSensor Will bhnk 1f it IS currently
not paired 1nlo a Z-Wave network when pressing the
Z-Wave Bullon
Adding/Including/Pairing the MultiSensor into a
Z-Wave Network
Warranty
Customer must prepay sh1pping and transportatbn charges for returned
Products. and 1nsure the shipment or accept the nsk of loss or damage
during such !:>hipmont and transportation. Aeun Labs wilt ship the
repaired or replacement products to Customer freight prepaid.
Customer shall 1ndemmfy, defend, and hold Aeon Labs and Aeon Labs'
affiliates, shareholders, directors. officers. employees, contractors,
agents and other representatwes harmless from all demands, cla1ms,
actions. causes of action, proceed1ngs, su1ts, assessments, losses,
damages, liabilities, settlemen ts, judgments. f.nes, penalt1es, 1nterest,
costs and expenses (includ1ng fees and disbursements of counsel) or
every kind (1) based upon personal injury or death or tnjury to property to
the extent any of the foregoing is prox1mately caused either by a
defective product (including strict liability in tort) or by the negligent or
willful acts or om1ssions of Customer or 1Ui officers, employees.
subcon tractors or agents, and/or (ii) arising from or relating to any actual
or alleged infringement or m1sappropnat1on of any patent, trademark,
mask work , copynght, trade secret or any actual o r alleged violation of
any other intellectual property rights ansing from or in connect1on w1th
the products, except to the extent that such tnfnngement ex1sts as a
result of Aeon Labs' manufacturing processes.
IN NO EVENT SHALL AEON LABS BE LIABLE FOR ANY INDIRECT,
INCIDENTAL,
PUNITIVE.
SPECIAL
OR
CONSEQUENTIAL
DAMAGES. OR DAMAGES FOR LOSS OF PROFITS, REVENUE, OR
USE INCURRED BY CUSTOMER OR ANY THIRD PARTY, W HETHER
IN AN ACTION IN CONTRACT, OR TORT, OR OTHERWISE EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. AEON LABS'
LIABILITY AND CUSTOMER'S EXCLUSIVE REMEDY FOR ANY
CAUSE OF ACTION ARISING IN CONNECTION WITH THIS
AGREEMENT OR THE SALE OR USE OF THE PRODUCTS,
WHETHER BASED ON NEGLIGENCE, STRICT LIABILITY, BREACH
OF WARRANTY, BREACH OF AGREEMENT, OR EQUITABLE
PRINCIPLES. IS EXPRESSLY LIMITED TO, AT AEOTEC'S OPTION,
REPLACEMENT OF, OR REPAYMENT OF THE PURCHASE PRICE
FOR THAT PORTION OF PRODUCTS WITH RESPECT TO WHICH
DAMAGES ARE CLAIMED. ALL CLAIMS OF ANY KIND ARISING IN
CONNECTION WITH THI S AGREEMENT OR THE SALE OR USE OF
PRODUCTS SHALL BE DEEMED WAIVED UNLESS MADE IN
WRITING WI THIN THIRTY (30) DAYS FROM AEON LABS' DELIVERY,
OR THE DATE FIXED FOR DELIVERY IN THE EVENT OF
NONDELIVERY.
1 This device may not cause harmful interference. and
2.This dev1ce must accept any Interference rece1ved, 1ncluding
interference that may cause undesired operat1on. This eqUipment has
been tested and found to comply w1th the hm1ts for a Class B digital
device, pursuant to part 15 of the FCC Rules. These lim1ts are designed
to provide reasonable protection against harmful interference In a
restdenllal installation. This equipment generates, uses and can radiate
rad10 frequency energy and. if not 1nstalled and used 10 accordance w1th
the instructions, may cause harmful intorforonco to radio
communications. However. there IS no guarantee that interference will
not occur 1n a part1cular installation. If th1s eqUipment does cause
harmful interference to rad10 or teleVISIOn reception, which can be
determ~ned by turn1ng the equ1pment off and on. the user IS encouraged
to try to correct the interference by one or more of the followmg
measures·
aReonent or relocate the receiVIng antenna
alncrease the separation between the eqUipment and receiver
•Connect the eqUipment into an outlet on a circuit d1tferent from that
to wh1ch the receiver is connected
•Consult the dealer or an expenenced radiO/TV techniCian for help.
Warning:
Do not dispose or electncal appliances as unsorted mun1cipal waste.
use separate collect1on faciht1es.
Contact your local govemment for 1nforma11on regarding the collection
systems available
Certifications (regional):
Do not dispose of electrical appliances as unsorted mume~pal waste,
use separate collection facilities.
Contact your local government for mformatJon regarding the collection
systems available.
CE e Cfe
www.aeon-labs.com
www.aeotec.com
AEON LABS