9-30 Function Parameters Setting range: 0~9999 F502 Selection of number of cycles of (when the value is set to 0, the Auto-circulation Speed Control inverter will carry out infinite circulating) F503 Status After Auto-circulation Running Finished. Mfr’s value: 0 Setting range: 0: Stop 1: Keep running at last-stage speed Mfr’s value: 0 If running mode is auto-circulation speed control (F203=4 and F500=2), please set the related parameters by F501~F503. The inverter runs at the preset stage speed one by one under the auto-circulation speed control is called as cycle. If F502=0, inverter will run at infinite auto circulation, which will be stopped by “stop” signal. If F502>0, inverter will run at auto circulation conditionally. When auto circulation of the preset cycles is finished continuously (set by F502), inverter will finish auto-circulation running conditionally. When inverter keeps running and the preset cycles is not finished, if inverter receives “stop command”, inverter will stop. If inverter receives “run command” again, inverter will automatically circulate by the setting time of F502. If F503=0, then inverter will stop after auto circulation is finished. If F503=1, then inverter will run at the speed of the last-stage after auto-circulation is finished as follows: e.g., F501=3, then inverter will run at auto circulation of 3-stage speed; F502=100, then inverter will run 100 cycles of auto circulation; F503=1, inverter will run at the speed of the last stage after the auto-circulation running is finished. Start auto circulating running Stage-1 speed Figure 9-10 Stage-2 speed Stage-3 speed After circulating 100 times Keep running at Stage-3 speed Auto-circulating Running The inverter can be stopped by pressing “O” or sending “O” signal through terminal during auto-circulation running. F504 Frequency setting for stage 1 speed (Hz) Mfr’s value: 5.00 F505 Frequency setting for stage 2 speed (Hz) Mfr’s value: 10.00 F506 Frequency setting for stage 3 speed (Hz) Mfr’s value: 15.00 F507 Frequency setting for stage 4 speed (Hz) Mfr’s value: 20.00 F508 Frequency setting for stage 5 speed (Hz) Mfr’s value: 25.00 F509 Frequency setting for stage 6 speed (Hz) Setting range: Mfr’s value: 30.00 F510 Frequency setting for stage 7 speed (Hz) F112~F111 Mfr’s value: 35.00 F511 Frequency setting for stage 8 speed (Hz) Mfr’s value: 40.00 F512 Frequency setting for stage 9 speed (Hz) Mfr’s value: 5.00 F513 Frequency setting for stage 10 speed (Hz) Mfr’s value: 10.00 F514 Frequency setting for stage 11 speed (Hz) Mfr’s value: 15.00 F515 Frequency setting for stage 12 speed (Hz) Mfr’s value: 20.00 AC10 Inverter