Appendix A. Specifications
A.3 Electronics
Enclosures
Epoxy coated, copper free, aluminum, weatherproof (IP67)
Electronics Classifications (Pending)
USA/Canada- Explosion-proof Class I, Division 1, Groups B, C, & D
ATEX - Flameproof II 2 G Ex d IIC T6 Gb
IECEx - Flameproof Ex d IIC T6 Gb
ROHS compliance
(Category 9 Exemption)
CE (EMC directive 2004/108/EC, LVD 2006/95/EC)
WEEE Compliance
Note: The electronics package includes an installed battery which shall only be replaced at a GE Service center.
Replacement involves de-soldering battery contacts, which could lead to a breach of Functional Safety. Please
contact GE Service to get this battery replaced.
Electronics Mounting
Local Mounting (on meter body)
Remote Mounting (up to 100 ft / 30.4 m). Recommended for process temperatures exceeding 150°C.
Channels
One or Two (two channels for two-path averaging)
Display Languages
English
Keypad
Built-in magnetic, six-button keypad, for full functionality operation
Inputs/Outputs
Option A: One analog output/SIL with HART**, two digital* outputs, service/Modbus(RS485) output, calibration
output
Option B: One analog output/SIL with HART**, one additional analog output**, two digital* outputs,
service/Modbus(RS485) output, calibration output
*Digital outputs are programmable as either pulse, frequency, alarm, or control outputs
**Analog outputs are NAMUR NE43 compliant
PanaFlow HT User’s Manual
85