Download INTEGRAL Science Data Centre IBIS Analysis User Manual
Transcript
IBIS SPS E band min m string List of lower limits of output energy bands for multiple default: ‘‘ ’’ IBIS SPS E band max m string List of upper limits of output energy bands for multiple default: ‘‘ ’’ SCW2 ISPE idx isgrResp string DOL of the index of ISGRI response matrices default: ‘‘’’ SCW2 ISPE isgrarfDOL string DOL of the ARFs for XSPEC default: ‘‘’’ SCW2 ISPE DataMode integer Data Simulation mode default: 0 SCW2 ISPE MethodInt integer Method to be applied for the pixel value interpolation default: 1 SCW2 ISPE MethodFit integer Method to be applied for background and source intensity fitting default: 6 SCW2 ISPE isgrUnifDol string DOL of the ISGRI detector uniformity default: ‘‘’’ SCW2 ISPE tungAtt string DOL of the Tungsten attenuation length fits file default: ‘‘’’ SCW2 ISPE aluAtt string DOL of the Aluminium attenuation length fits file default: ‘‘’’ SCW2 ISPE leadAtt string DOL of the Lead attenuation length fits file default: ‘‘’’ SCW2 BIN cleanTrk integer Cleaning of cosmic-ray induced events. possible values: 0 = No 1 = Yes default: 0 SCW2 BIN I idxNoisy string DOL of the index of noisy maps. default: ‘‘’’ SCW2 BIN I idxLowThre string index of Low Threshold default: ‘‘’’ SCW2 BIN P inDead string DOL of the dead time data structure. default: ‘‘’’ SCW2 BIN P inGTI string DOL of the good time interval data structure. default: ‘‘’’ SCW2 BIN P HepiLut string DOL of the hepi lut default: ‘‘’’ ISDC – IBIS Analysis User Manual – Issue 5.1 108