Download User Manual - Trango Systems

Transcript
SYNTAX odupower odupower < on| off > Default: OFF Configuration Storage: Yes odupower without any parameter will display the current status of ODU power . DESCRIPTION The command is used to Turn ON/OFF odupower. The ODU is powered from the IDU over the IF cable with ‐48VDC It is recommended to turn off the ODU power during initial installing of the ODU on the tower and other maintenance The response time for ODU power ON will vary depending upon the ODU model. It is longer for HP ODUs odurxagc SYNTAX odurxagc <on | off> DEFAULT VALUE Off DESCRIPTION Trango Systems, Inc. The command is used to set the odurx gain control loop in the system. This controls the receive level into the IDU from the ODU and keeps the received level within a predefined range. This helps to improve MSE and maintain better system performance in fading conditions. GigaPlus User Manual Rev 3.0 171