Supplier’s name or trade mark
Supplier’s model identifier
Storage volume V in litres
Mixed water at 40 °C V40 in litres
The declared load profile
Premier Plus Solar
PES170D PES210D PES260D PES300D
170.0
210.0
260.0
300.0
105.7
205.3
258.5
279.5
M
L
L
L
The water heating energy efficiency class of the model
The water heating energy efficiency in %
The annual electricity consumption in kWh
Daily fuel consumption Q fuel in kWh
The thermostat temperature settings of the water heater,
as placed on the market by the supplier
Specific precautions that shall be taken when the water
heater is assembled, installed or maintained and disposed
of at end of life
Indirect
Model(s)
Energy efficiency class
Standing loss in W
Storage volume V in litres
C
C
C
C
37.4
1373
6.380
37.7
2716
12.580
38.9
2632
12.090
38.0
2697
12.470
60°C
See section 2 to 6
PES190I
C
80.0
190.0
PES210I
C
82.0
210.0
PES250I
D
94.0
250.0
PES300I
D
105.0
300.0
Table: Technical parameters in accordance with European Commission regulations 814/2013 and 812/2013
1.0 INTRODUCTION
The Premier Plus Solar is a purpose designed unvented solar water heater. The unit has a stainless steel inner
vessel which ensures an excellent standard of corrosion resistance. The outer casing is a combination of resilient
thermoplastic mouldings and corrosion proofed steel (Plastisol) sheet. All Premiers are insulated with CFC/HCFC
free polyurethane foam to meet the latest European heat loss requirements (see Table 3).
The unit is supplied complete with all the necessary safety and control devices needed to allow connection to the
PremierPlus solar cylinder. All these components are pre-adjusted.
This appliance complies with the requirements of the CE marking directive and is KIWA approved to show compliance
with Building Regulations (Section G3).
The following instructions are offered as a guide to installation which must be carried out by a competent plumbing
and electrical installer in accordance with Building Regulation G3, The Building Standards
NOTE: Prior to installation the unit should be stored in an upright position in an area free from excessive damp or
humidity.
Table 3: Standing heat losses
Table 2: Unit weights
Model
reference
Type
DIRECT
PES170D
PES210D
PES260D
PES300D
INDIRECT PES190I
PES210I
PES250I
PES300I
4
Nominal
capacity
(litres)
170
210
260
300
190
210
250
300
Weight of
unit full
(kg)
210
259
308
362
240
264
308
367
Standing Heat Loss
Nominal
Capacity
(litres)
per day
(kWh/24h)
per year
(kWh/365d)
170
190
210
250
260
300
1.40
1.52
1.70
1.96
1.98
2.28
511
555
621
715
723
832
Table: Figures measured in accordance with KIWA Test
Criteria for compliance with UK Building and Water
Regulations