Download TFXB Manual - Flow Meter Rentals
Transcript
06-TTM-UM-00006 10/2011 105 A B C D E F G H 11 9 CLASS I, DIVISION 1 GROUPS C AND D 12 NOTES: UNLESS OTHERWISE SPECIFIED 3. RADII TO BE .005/.010 2. FINISH TO BE 63 1. REMOVE ALL BURRS AND BREAK SHARP EDGES .005/.010 11 10 9 3' MIN. (0.93 METERS) (2 PLACES) DYNASONICS DTT SERIES TRANSDUCERS MODEL NO: DTTN-xxx-Axxx-F 8 7 TEE FITTING D002-1201-002 7 6 SEAL OFF CONDUIT PER INSTALLATION NOTES 6 & 7 990' MAX. (302 METERS) (RG-59/U COAX ONLY) FLEXIBLE ARMORED CONDUIT SUITABLE FOR INCIDENTAL AND TEMPORARY SUBMERSION D002-1401-003 6 5 5 10' MAX 4 BLACK BLACK SEE ABOVE MATERIAL: UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES TOLERANCE ON DECIMALS .00 ±.010, .000 ±.005 ANGLES ±1/2° I.S. WIRING 6.26 (MTG. HOLES) RED CONNECT TO TRANSMITTER PER INSTALLATION MANUAL RED NON-HAZARDOUS LOCATION 3 LTR A ZONE ALL DRAWN BY: 11/11/04 11/28/01 D091-1053-005 10/29/04 KOUN T. PAUL 3 REVISIONS DESCRIPTION 3.60 (MTG. HOLES) DATE 1 2 SCALE: D SIZE: NONE 59380 CODE I.D. NO. CURRENT REV: A 1 SHEET: 2 OF 2 D091-1053-005 PART NUMBER: APPROVAL 8635 Washington Avenue RACINE, WI. U.S.A. (262) 639-6770 H3791 11/11/04 E.C.O. CONTROL DRAWING I.S. BARRIER & DTT TRANSDUCERS NAME: I.S. MODULE PART NO. D070-1010-001 THIS DRAWING WAS DONE ON AUTOCAD AND CAN ONLY BE REVISED ON A AUTOCAD SYSTEM. ANY MANUAL CHANGES DONE TO THIS DRAWING WILL BE IGNORED UNLESS AUTHORIZED. DATE: SUPERSEDES: REVISED BY: ENGINEER: CHECKED BY: 2 UPDATED PER CSA DYNASONICS I.S. BARRIER MODEL D070-1010-002 MAXIMUM AMBIENT TEMPERATURE: -40°C TO 50°C 4 FIGURE A-6.2 - CONTROL DRAWING I.S. BARRIER DTT TRANSDUCERS FLEXIBLE CONDUIT SENSING SURFACE: COUPLE TO PIPE WITH RTV OR SILICONE GREASE SUPPLIED, PER INSTALLATION MANUAL TFXD O&M. HAZARDOUS (CLASSIFIED) LOCATION 8 MAXIMUM AMBIENT TEMPERATURE: -40° TO +85°C 1. REFER TO TRANSMITTER'S INSTALLATION MANUAL FOR TRANSDUCER LOCATION AND MOUNTING INSTRUCTIONS. 2. WARNING - TO PREVENT IGNITION OF FLAMMABLE ATMOSPHERES, DISCONNECT POWER BEFORE SERVICING. 3. WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY. 4. NO REVISION TO DRAWING WITHOUT PRIOR CSA-INTERNATIONAL APPROVAL. 5. ASSOCIATED APPARATUS MANUFACTURER'S INSTALLATION DRAWING MUST BE FOLLOWED WHEN INSTALLING THIS EQUIPMENT. 6. INSTALLATION IN CANADA SHOULD BE IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE, CSA C22.1, PART 1, APPENDIX F. 7. INSTALLATION SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (ANSI / NFPA 70) SECTIONS 504 AND 505 AND THE ANSI / ISA RP12.6 INSTALLATION OF INTRINSICALLY SAFE SYSTEMS FOR HAZARDOUS (CLASSIFIED) LOCATIONS. 8. THE MAXIMUM NON-HAZARDOUS LOCATION VOLTAGE IS 250V AC/DC. 10 D091-1053-005 12 THIS DRAWING IS PROPRIETARY TO RACINE FEDERATED INC. RECEIPT OR POSSESSION CONFERS NO RIGHT TO USE THE SUBJECT MATTER OF THIS DRAWING OR TECHNICAL INFORMATION SHOWN; NOR THE RIGHT TO REPRODUCE THIS DRAWING OR ANY PART EXCEPT FOR THOSE SUPPLIERS OF RACINE FEDERATED INC. WHO RECEIVE A WRITTEN REQUEST FOR MANUFACTURE OR SIMILAR USE. PART NUMBER: A B C D E F G H