Download TFXB Manual - Flow Meter Rentals

Transcript
06-TTM-UM-00006 10/2011
105
A
B
C
D
E
F
G
H
11
9
CLASS I, DIVISION 1 GROUPS C AND D
12
NOTES: UNLESS OTHERWISE SPECIFIED
3. RADII TO BE .005/.010
2. FINISH TO BE 63
1. REMOVE ALL BURRS AND BREAK SHARP EDGES .005/.010
11
10
9
3' MIN.
(0.93 METERS)
(2 PLACES)
DYNASONICS DTT SERIES
TRANSDUCERS
MODEL NO: DTTN-xxx-Axxx-F
8
7
TEE FITTING
D002-1201-002
7
6
SEAL OFF CONDUIT
PER INSTALLATION
NOTES 6 & 7
990' MAX.
(302 METERS)
(RG-59/U COAX ONLY)
FLEXIBLE ARMORED
CONDUIT SUITABLE
FOR INCIDENTAL AND
TEMPORARY SUBMERSION
D002-1401-003
6
5
5
10' MAX
4
BLACK
BLACK
SEE
ABOVE
MATERIAL:
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
TOLERANCE ON DECIMALS
.00 ±.010, .000 ±.005
ANGLES ±1/2°
I.S. WIRING
6.26
(MTG. HOLES)
RED
CONNECT TO
TRANSMITTER PER
INSTALLATION
MANUAL
RED
NON-HAZARDOUS LOCATION
3
LTR
A
ZONE
ALL
DRAWN BY:
11/11/04
11/28/01
D091-1053-005
10/29/04
KOUN
T. PAUL
3
REVISIONS
DESCRIPTION
3.60
(MTG. HOLES)
DATE
1
2
SCALE:
D
SIZE:
NONE
59380
CODE I.D. NO.
CURRENT REV:
A
1
SHEET:
2 OF 2
D091-1053-005
PART NUMBER:
APPROVAL
8635 Washington Avenue
RACINE, WI. U.S.A.
(262) 639-6770
H3791 11/11/04
E.C.O.
CONTROL DRAWING
I.S. BARRIER & DTT TRANSDUCERS
NAME:
I.S. MODULE
PART NO. D070-1010-001
THIS DRAWING WAS DONE ON AUTOCAD AND
CAN ONLY BE REVISED ON A AUTOCAD SYSTEM.
ANY MANUAL CHANGES DONE TO THIS DRAWING
WILL BE IGNORED UNLESS AUTHORIZED.
DATE:
SUPERSEDES:
REVISED BY:
ENGINEER:
CHECKED BY:
2
UPDATED PER CSA
DYNASONICS I.S. BARRIER
MODEL D070-1010-002
MAXIMUM AMBIENT TEMPERATURE: -40°C TO 50°C
4
FIGURE A-6.2 - CONTROL DRAWING I.S. BARRIER DTT TRANSDUCERS FLEXIBLE CONDUIT
SENSING SURFACE: COUPLE TO
PIPE WITH RTV OR SILICONE
GREASE SUPPLIED, PER INSTALLATION
MANUAL TFXD O&M.
HAZARDOUS (CLASSIFIED) LOCATION
8
MAXIMUM AMBIENT TEMPERATURE: -40° TO +85°C
1. REFER TO TRANSMITTER'S INSTALLATION MANUAL FOR TRANSDUCER LOCATION AND MOUNTING INSTRUCTIONS.
2. WARNING - TO PREVENT IGNITION OF FLAMMABLE ATMOSPHERES, DISCONNECT POWER BEFORE SERVICING.
3. WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY.
4. NO REVISION TO DRAWING WITHOUT PRIOR CSA-INTERNATIONAL APPROVAL.
5. ASSOCIATED APPARATUS MANUFACTURER'S INSTALLATION DRAWING MUST BE FOLLOWED WHEN INSTALLING THIS EQUIPMENT.
6. INSTALLATION IN CANADA SHOULD BE IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE, CSA C22.1, PART 1, APPENDIX F.
7. INSTALLATION SHALL BE IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE (ANSI / NFPA 70) SECTIONS 504 AND 505 AND THE
ANSI / ISA RP12.6 INSTALLATION OF INTRINSICALLY SAFE
SYSTEMS FOR HAZARDOUS (CLASSIFIED) LOCATIONS.
8. THE MAXIMUM NON-HAZARDOUS LOCATION VOLTAGE IS 250V AC/DC.
10
D091-1053-005
12
THIS DRAWING IS PROPRIETARY TO RACINE FEDERATED INC. RECEIPT OR POSSESSION CONFERS NO RIGHT TO USE
THE SUBJECT MATTER OF THIS DRAWING OR TECHNICAL INFORMATION SHOWN; NOR THE RIGHT TO REPRODUCE THIS
DRAWING OR ANY PART EXCEPT FOR THOSE SUPPLIERS OF RACINE FEDERATED INC. WHO RECEIVE A WRITTEN
REQUEST FOR MANUFACTURE OR SIMILAR USE.
PART NUMBER:
A
B
C
D
E
F
G
H