Download FB Library Start-up Guide

Transcript
2-8 RFID (ID Sensor)
V600-H††
2-4. Usage Example of FB Component
FB “Write Data to Data Carrier”
FB Name
_V60x400_WriteData
File Name
_V60x400_WriteData10.cxf
Functional Overview
Writes data to a Data Carrier.
Program Example
When contact W0.00 is ON, ID sensor writes data “12 34 56 78” into carrier’s address 10.
After normal write, contact W0.02 is set to ON by 1 cycle.
If an error occurs by any reason, contact W0.03 is set to ON by 1 cycle.
A200.11
W0.0
↑
Unit No.
&1
Head No.
&1
Data Carrier write address
&10
Bytes to process in Data Carrier
&4
Write data storage area type
P_DM
Write data storage word address
&1000
Communications designation
&0
Processing designation
&0
Cancel
W0.15
W0.1
MOV #1234 D1000
MOV #5678 D1001
_V60x400_WriteData
(BOOL)
(BOOL)
EN
ENO
(INT)
(BOOL)
UnitNo
BUSY
(INT)
(BOOL)
HeadNo
OK
(WORD)
(BOOL)
CarrierAddress
NG
(INT)
(WORD)
WriteBytes
ErrorCode
(WORD)
DataAreaID
(INT)
DataAreaNo
(INT)
Communications
(INT)
ByteOrder
(BOOL)
Cancel
Busy flag
W0.0
Normal end
W0.2
Error end
W0.3