Installation
SELF CONTAINED (LOCATION)
G SVM
G SVM
GSVM-4060 and GSVM-4072 (at 75°F/55%
relative humidity, maximum ambient conditions) has front condenser air intake and discharge. Maintain a minimum clearance distance
of two feet in front of the merchandiser so that
air discharge and air intake is not obstructed.
GSVM-4072 (at 80°F/55% relative humidity,
maximum ambient conditions) and
GSVM-5272 each require a 5 inch minimum
clearance behind the merchandiser and clearance above the merchandiser since its air flows
straight through the condensing unit compartment. Brackets are provided for field attachment
to obtain this rear 5 inch minimum clearance.
G SVM -5272
G SVM -4072