Download "service manual"

Transcript
'RPHVWLFDLUFRQGLWLRQHU
6(59,&(0$18$/
TEMPERATURE
5
6
7
4
3
8
9
2
1
MIN
COOL
0RGHO
10
MAX
COOL
FAN ONLY
HI
LOW
SPEED
ON
HW-05C03/R1
OFF
POWER
Wait 3 Minutes Before
Restarting
zFeatures
zTop-Discharge Air Flow
zUltra Quiet Operation
zSafty Power Cord
zEnvicoCleanTMCoil
zEasy-Access Washable Filter
zDigital Display&Timer
zEnergy Star(ESA3056)
Serial Number:
Version:00.00
Edition: 2007-2-4
Haier air conditioner
Edition: 1.0-070204
Content
1. Product Code Illumination and Series introduction...........................3
2. Specifications....................................................................................4
3. Safety and Precaution.......................................................................5
4. Warning and Cautions.......................................................................6
5. Installation and Accessory Parts........................................................7
6. Parts and Functions.........................................................................12
7. Abnormity Diagnose.........................................................................13
8. System Flow Chart...........................................................................14
9. Wiring Diagram................................................................................15
-2-
Haier air conditioner
Edition: 1.0-061231
Introductory Remarks
Description of coding rules of unit model
Coding rules and descriptions are as follows:
1
2
4
5
6
7
8
9
10
11
Refrigerant type:R1(R407C),R2(R410A)
Applicable voltage:3(220~230V),4(240V)
Applicable frequency:0(50HZ),1(60HZ)
Developing sequence :A,B,C,D...
L/C-cooling only
Function code R/H-heat pump
E-electric aided heating
Nominal cooling capacity (BTU/h)with the first two
numbers based on thousand unit
The structure code of indoor & outdoor unit: S(wall-mounted),W(window type),P (cabinet type)
H-Abbreviation of Haier
Examples:
HW-05C03/R1 represents Abbreviation of Window air conditioner .
The cooling capacity is 5000BTU/h and the power supply is 220-230V/50Hz
the refrigerant is R407C
Haier air conditioner
Edition: 1.0-061231
6SHFLILFDWLRQV
,WHP
81,7
+:&5
&RROLQJFDSDFLW\
%78K
+HDWLQJFDSDFLW\
%78K
3RZHUVXSSO\
&RROLQJ
3+9+]
3RZHULQSXW
:
5XQQLQJFXUUHQW
$
((5
+HDWLQJ
%78K:
5XQQLQJFXUUHQW
$
%78K:
,QGRRUVLGH G%$
2XWGRRUVLGH G%$
:LGWK
PP
'HSWK
PP
+HLJKW
PP
3DFNDJLQJGLPHQVLRQV :LGWK
PP
'HSWK
PP
1HW
OEV
*URVV
OEV
7\SH
0RGHO
&RPSUHVVRU
5XQQLQJFDSIRU
FRPS
‡ ‡)
6WDUWLQJPHWKRG
3UHVVXUH
5HIULJHUDQW
7\SH
+HDWLQJVLGH
3VLJ
&RROLQJVLGH
3VLJ
0RGHO
&KDUJH
LQGRRUXQLW
)DQVSHHG RXWGRRUXQLW
$LUYROXPH
0RLVWXUHUHPRYDO
Exchanging pipe type/ diameter
)LQ PDWHULDO
NJ
5RWDWH
3*;&%*
XI9$&
36&
5&
$FHQWULFIDQ
$[LDOIDQ
RXWGRRUXQLW
LQGRRUXQLW
)DQ
PP
:HLJKW
:
+HLJKW
&DVH
3RZHULQSXW
&23
6RXQG/HYHO
ff
f
UPLQ
ff
f
&)0
3LQWVKU
Evaporator:ï
mm
7condenser:ï7
+\GURSKLOH
DOXPLQXPIRLO
UPLQ
Haier air conditioner
Edition: 1.0-061231
3. Safety and Precaution
WARNING: Following these basic precautions will reduce the risk of
fire, electrical shock, injury or death when using your air
conditioner.
1) Air conditioner must be connected to proper electrical outlet with the correct electrical supply.
(See table)
2) Proper grounding must be ensured to reduce the risk of shock and fire.
DO NOT CUT OR REMOVE THE GROUNDING PRONG.
If you do not have a three-prong electric receptacle outlet in the wall, have a certified electrician
install the proper receptacle. The wall receptacle MUST be properly grounded.
3) DO not use if power cord is frayed or damage. Also avoid using if there are cracks or abrasion
damage along the length, plug or connector.
4) DO NOT USE AN ADAPTER OR AN EXTENSION CORD.
5) When installing your air conditioner in a window, make sure the window is strong enough to
hold the weight of he air conditioner. You also want to secure and correctly install your air
conditioner property to prevent it from falling. Extra brackets or support may be required
depending on your window.
6) Do not black airflow inside or outside the air conditioner with blinds, drapes, protective covers,
shrubs or bushes.
7) Be careful of sharp edges on the front and rear fins of the unit that could cut and cause serious
injury.
8) Be careful when lifting the air conditioner to install or remove the unit. Always use two or more
people for this.
9) Always unplug the air conditioner before servicing it or moving it.
-4 -
Haier air conditioner
Edition: 1.0-061231
3. Safety and Precaution
WARNING: Following these basic precautions will reduce the risk of
fire, electrical shock, injury or death when using your air
conditioner.
1) Air conditioner must be connected to proper electrical outlet with the correct electrical supply.
(See table)
2) Proper grounding must be ensured to reduce the risk of shock and fire.
DO NOT CUT OR REMOVE THE GROUNDING PRONG.
If you do not have a three-prong electric receptacle outlet in the wall, have a certified electrician
install the proper receptacle. The wall receptacle MUST be properly grounded.
3) DO not use if power cord is frayed or damage. Also avoid using if there are cracks or abrasion
damage along the length, plug or connector.
4) DO NOT USE AN ADAPTER OR AN EXTENSION CORD.
5) When installing your air conditioner in a window, make sure the window is strong enough to
hold the weight of he air conditioner. You also want to secure and correctly install your air
conditioner property to prevent it from falling. Extra brackets or support may be required
depending on your window.
6) Do not black airflow inside or outside the air conditioner with blinds, drapes, protective covers,
shrubs or bushes.
7) Be careful of sharp edges on the front and rear fins of the unit that could cut and cause serious
injury.
8) Be careful when lifting the air conditioner to install or remove the unit. Always use two or more
people for this.
9) Always unplug the air conditioner before servicing it or moving it.
-5-
Haier air conditioner
Edition: 1.0-061231
4. Warning and Cautions
WARNINGS: Following the safety messages is very important.
These messages can save you from being injured or killed. Warning symbols alert
you to be careful and means Danger. Always follow instructions to be safe and
reduce chances of injury or death. Warning and Danger signs will precede safety
messages.
Electrical Safety
Grounding: This room air conditioner must be grounded. Grounding reduces the risk of electric
shock by providing an escape wire for the electric current. The power cord has a
grounding wire with a grounding plug. Plug it into an outlet that is properly installed
and grounded.
WARNING:
Improper use of the grounding plug can result in a risk of electric shock. Call a
qualified electrician if you don't understand the grounding instructions or if you are
not sure if the air conditioner is properly grounded. If the wall outlet is not grounded,
please contact an electrician to have it replaced with a properly grounded outlet.
Do not, under any circumstances, cut or remove the third (ground) prong from the
power cord.
Adapter Plug: We strongly advise against using an adapter plug.
-6-
Haier air conditioner
Installation and Accessory Parts
7
Edition: 1.0-061231
Haier air conditioner
Installation and Accessory Parts
HWR06XC6,ESA3056
HWF06XC5
HWR
06XC5, ESA3055
3
5 25
12 35
13 25
33 15
22 12
7
1216
9
1816
13 38
ASSEMBLE
CURTAINS/ TOP RAIL
Install top rail with 3 short
screws13/ 32".
Insert the side curtains into the
top and bottom rails of the air
conditioner. Fasten the curtains
to the unit with 8 short screws
13/ 32".
8
Edition: 1.0-061231
Haier air conditioner
2
Edition: 1.0-061231
INNER
SILL
1. This unit is designed for installation in standard double hung windows
with actual opening widths of 22 to 36 . The upper and lower sash
must open sufficiently to allow a clear vertical opening of 14 from the
bottom of the sash to the window stool.
2. If storm window presents interference, fasten a 2 wide wood strip(not
included) (OUTER SILL) to the inner window sill across the full width of
the sill. The wood strip should be thick enough to raise the height of
the window sill so that the unit can be installed without interference by
the storm window frame (STORM WINDO W FRAME) or wood strip
(O UTDOO RS) to help condensation to drain properly to the outside.
3. Install a second wood strip (approximately 6 long by 3/ 2 wide and
same thickness as first strip) in the center of the outer sill flush against
the back off the inner sill. This will raise basepan angle .
4. If the distance between STORM WINDOW FRAME and WOOD STRIP
MO UNTED ON TO P OF INNER SILL is more than 1 , two of wood
strip are not necessary.
LOCATING UNIT IN
WINDOW
Open the window and mark center line on the
center of the inner sill.
O
U
T
D
O
O
OUTER R
SILL
S
I
N
D
O
O
R
S
1 MAX.
WO OD STRIP
MO UNTED ON
TO P OF INNER SILL
STO RM
WINDO W FRAME
INNER
SILL
WOO D STRIP
I FO R BASEPAN
N ANGLE
D
O
O
R
S
CENTER LINE
OUTER
SILL
O
U
T
D
O
O
R
S
ATTACH BASEPAN
ANGLE
Install the basepan angle behind the inner window sill, with
the short side of basepan angle as shown. Use the 2 short
screws13/ 32" provided.
The basepan angle helps to hold unit securely in place.
Be sure to place basepan angle edge flush against back
of inner sill.
INNER SILL
INNER SILL
3/ 4 CLEARANCE
SHORT SCREW13/ 32"
CENTER LINE
OUTER SILL
IN SIDE
8
INDO OR SIDE
SHORT SIDE
8
OUTSIDE
BASEPAN ANGLE
9
Haier air conditioner
Edition: 1.0-061231
Installation and Accessory Parts
INSTALL THE AIR CONDITIONER
IN THE WINDOW
WINDOW FRAME
UPPER GUIDE
Carefully lift the air conditioner and slide it into the open
window. Make sure the bottom guide of the air conditioner
drops into the notches of the basepan angle.
While steadying the air conditioner ,carefully bring the
window sash down behind the upper guide of the air
conditioner.
ABOUT 1/ 4
BOTTOM GUIDE
BASEPAN ANGLE
INSTALL THE SEAL GASKET
AND SASH LOCK
WINDO W SEAL GASKET
BASEPAN ANGLE
SHORT SCREW13/ 32"
Extend the side curtains to fill the
window opening using 4 wood screws
31/ 32" to secure them.
Cut the seal gasket to the window
width. Stuff the sash seal between the
glass and the window to prevent air
and insects from getting into the room.
Fasten the basepan angle, using a
short screw13/ 32".
WO OD SCREW31/ 32"
10
Haier air conditioner
Installation and Accessory Parts
wood screws 31/ 32"
top rail
ON/OFF
MODE
SPEED
TIMER
TEMP/TIME
window seal gasket
short screws 13/ 32"
Remote
control
“ CR2025“ battery
Model:HWR06XC5, ESA3055
11
Edition: 1.0-061231
Haier air conditioner
Parts and Functions
12
Edition: 1.0-061231
Haier air conditioner
Edition: 1.0-061231
Abnormity Diagnose
1. Sensor diagnose: 2 seconds after the sensors open circuit or short
circuit, the unit will turn off automatically and the LED will show E0 until
the sensors resume.
2. Keystroke circuit error diagnose: When power on for the first time, the
PCB will check the keystroke circuit, if the sampling value is different with
the theory value, the LED will show E1, which means failed keystroke
circuit. The keyboard is locked and so invalid, but the remote control is
working normally.
13
Haier air conditioner
Edition: 1.0-061231
System Flow Chart
Indoor
heat exchanger
Outdoor
heat exchanger
Compressor
Capacillary tube
Cooling
14
HIGH 1
ON 1
B (Plain)
Y/G (G)
W (Ribbed)
B:BLACK
Y:YELLOW
GR:GREY
R:RED
G:GREEN
POWER SUPPLY
BL:BLUE
Y/G:YELLOW/GREEN
0010552091
WIRING DIAGRAM
SWITCH 1
OFF
SWITCH 2
2 3 LOW
2
B
L
B
ROOM
THERMOSTAT
C
OVERLOAD
RELAY
R
H
L
~
GR
R
CAPACITOR
M
FAN MOTOR
OR
COMPRESSOR
MR
C
~
S
W
BL
B
HWR06XC6 ESA3056
CAPACITOR
Note: Because of the difference of compressor,
the dotted line part may not exist.
15
Edition: 1.0-061231
Haier air conditioner
Wiring Diagram
Haier air conditioner
Edition: 1.0-061231
Sincere Forever
Haier Group
Haier Industrial Park, No.1, Haier Road
266101, Qingdao, China
http://www.haier.com
16