Download "service manual"
Transcript
'RPHVWLFDLUFRQGLWLRQHU 6(59,&(0$18$/ TEMPERATURE 5 6 7 4 3 8 9 2 1 MIN COOL 0RGHO 10 MAX COOL FAN ONLY HI LOW SPEED ON HW-05C03/R1 OFF POWER Wait 3 Minutes Before Restarting zFeatures zTop-Discharge Air Flow zUltra Quiet Operation zSafty Power Cord zEnvicoCleanTMCoil zEasy-Access Washable Filter zDigital Display&Timer zEnergy Star(ESA3056) Serial Number: Version:00.00 Edition: 2007-2-4 Haier air conditioner Edition: 1.0-070204 Content 1. Product Code Illumination and Series introduction...........................3 2. Specifications....................................................................................4 3. Safety and Precaution.......................................................................5 4. Warning and Cautions.......................................................................6 5. Installation and Accessory Parts........................................................7 6. Parts and Functions.........................................................................12 7. Abnormity Diagnose.........................................................................13 8. System Flow Chart...........................................................................14 9. Wiring Diagram................................................................................15 -2- Haier air conditioner Edition: 1.0-061231 Introductory Remarks Description of coding rules of unit model Coding rules and descriptions are as follows: 1 2 4 5 6 7 8 9 10 11 Refrigerant type:R1(R407C),R2(R410A) Applicable voltage:3(220~230V),4(240V) Applicable frequency:0(50HZ),1(60HZ) Developing sequence :A,B,C,D... L/C-cooling only Function code R/H-heat pump E-electric aided heating Nominal cooling capacity (BTU/h)with the first two numbers based on thousand unit The structure code of indoor & outdoor unit: S(wall-mounted),W(window type),P (cabinet type) H-Abbreviation of Haier Examples: HW-05C03/R1 represents Abbreviation of Window air conditioner . The cooling capacity is 5000BTU/h and the power supply is 220-230V/50Hz the refrigerant is R407C Haier air conditioner Edition: 1.0-061231 6SHFLILFDWLRQV ,WHP 81,7 +:&5 &RROLQJFDSDFLW\ %78K +HDWLQJFDSDFLW\ %78K 3RZHUVXSSO\ &RROLQJ 3+9+] 3RZHULQSXW : 5XQQLQJFXUUHQW $ ((5 +HDWLQJ %78K: 5XQQLQJFXUUHQW $ %78K: ,QGRRUVLGH G%$ 2XWGRRUVLGH G%$ :LGWK PP 'HSWK PP +HLJKW PP 3DFNDJLQJGLPHQVLRQV :LGWK PP 'HSWK PP 1HW OEV *URVV OEV 7\SH 0RGHO &RPSUHVVRU 5XQQLQJFDSIRU FRPS ) 6WDUWLQJPHWKRG 3UHVVXUH 5HIULJHUDQW 7\SH +HDWLQJVLGH 3VLJ &RROLQJVLGH 3VLJ 0RGHO &KDUJH LQGRRUXQLW )DQVSHHG RXWGRRUXQLW $LUYROXPH 0RLVWXUHUHPRYDO Exchanging pipe type/ diameter )LQ PDWHULDO NJ 5RWDWH 3*;&%* XI9$& 36& 5& $FHQWULFIDQ $[LDOIDQ RXWGRRUXQLW LQGRRUXQLW )DQ PP :HLJKW : +HLJKW &DVH 3RZHULQSXW &23 6RXQG/HYHO ff f UPLQ ff f &)0 3LQWVKU Evaporator:ï mm 7condenser:ï7 +\GURSKLOH DOXPLQXPIRLO UPLQ Haier air conditioner Edition: 1.0-061231 3. Safety and Precaution WARNING: Following these basic precautions will reduce the risk of fire, electrical shock, injury or death when using your air conditioner. 1) Air conditioner must be connected to proper electrical outlet with the correct electrical supply. (See table) 2) Proper grounding must be ensured to reduce the risk of shock and fire. DO NOT CUT OR REMOVE THE GROUNDING PRONG. If you do not have a three-prong electric receptacle outlet in the wall, have a certified electrician install the proper receptacle. The wall receptacle MUST be properly grounded. 3) DO not use if power cord is frayed or damage. Also avoid using if there are cracks or abrasion damage along the length, plug or connector. 4) DO NOT USE AN ADAPTER OR AN EXTENSION CORD. 5) When installing your air conditioner in a window, make sure the window is strong enough to hold the weight of he air conditioner. You also want to secure and correctly install your air conditioner property to prevent it from falling. Extra brackets or support may be required depending on your window. 6) Do not black airflow inside or outside the air conditioner with blinds, drapes, protective covers, shrubs or bushes. 7) Be careful of sharp edges on the front and rear fins of the unit that could cut and cause serious injury. 8) Be careful when lifting the air conditioner to install or remove the unit. Always use two or more people for this. 9) Always unplug the air conditioner before servicing it or moving it. -4 - Haier air conditioner Edition: 1.0-061231 3. Safety and Precaution WARNING: Following these basic precautions will reduce the risk of fire, electrical shock, injury or death when using your air conditioner. 1) Air conditioner must be connected to proper electrical outlet with the correct electrical supply. (See table) 2) Proper grounding must be ensured to reduce the risk of shock and fire. DO NOT CUT OR REMOVE THE GROUNDING PRONG. If you do not have a three-prong electric receptacle outlet in the wall, have a certified electrician install the proper receptacle. The wall receptacle MUST be properly grounded. 3) DO not use if power cord is frayed or damage. Also avoid using if there are cracks or abrasion damage along the length, plug or connector. 4) DO NOT USE AN ADAPTER OR AN EXTENSION CORD. 5) When installing your air conditioner in a window, make sure the window is strong enough to hold the weight of he air conditioner. You also want to secure and correctly install your air conditioner property to prevent it from falling. Extra brackets or support may be required depending on your window. 6) Do not black airflow inside or outside the air conditioner with blinds, drapes, protective covers, shrubs or bushes. 7) Be careful of sharp edges on the front and rear fins of the unit that could cut and cause serious injury. 8) Be careful when lifting the air conditioner to install or remove the unit. Always use two or more people for this. 9) Always unplug the air conditioner before servicing it or moving it. -5- Haier air conditioner Edition: 1.0-061231 4. Warning and Cautions WARNINGS: Following the safety messages is very important. These messages can save you from being injured or killed. Warning symbols alert you to be careful and means Danger. Always follow instructions to be safe and reduce chances of injury or death. Warning and Danger signs will precede safety messages. Electrical Safety Grounding: This room air conditioner must be grounded. Grounding reduces the risk of electric shock by providing an escape wire for the electric current. The power cord has a grounding wire with a grounding plug. Plug it into an outlet that is properly installed and grounded. WARNING: Improper use of the grounding plug can result in a risk of electric shock. Call a qualified electrician if you don't understand the grounding instructions or if you are not sure if the air conditioner is properly grounded. If the wall outlet is not grounded, please contact an electrician to have it replaced with a properly grounded outlet. Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. Adapter Plug: We strongly advise against using an adapter plug. -6- Haier air conditioner Installation and Accessory Parts 7 Edition: 1.0-061231 Haier air conditioner Installation and Accessory Parts HWR06XC6,ESA3056 HWF06XC5 HWR 06XC5, ESA3055 3 5 25 12 35 13 25 33 15 22 12 7 1216 9 1816 13 38 ASSEMBLE CURTAINS/ TOP RAIL Install top rail with 3 short screws13/ 32". Insert the side curtains into the top and bottom rails of the air conditioner. Fasten the curtains to the unit with 8 short screws 13/ 32". 8 Edition: 1.0-061231 Haier air conditioner 2 Edition: 1.0-061231 INNER SILL 1. This unit is designed for installation in standard double hung windows with actual opening widths of 22 to 36 . The upper and lower sash must open sufficiently to allow a clear vertical opening of 14 from the bottom of the sash to the window stool. 2. If storm window presents interference, fasten a 2 wide wood strip(not included) (OUTER SILL) to the inner window sill across the full width of the sill. The wood strip should be thick enough to raise the height of the window sill so that the unit can be installed without interference by the storm window frame (STORM WINDO W FRAME) or wood strip (O UTDOO RS) to help condensation to drain properly to the outside. 3. Install a second wood strip (approximately 6 long by 3/ 2 wide and same thickness as first strip) in the center of the outer sill flush against the back off the inner sill. This will raise basepan angle . 4. If the distance between STORM WINDOW FRAME and WOOD STRIP MO UNTED ON TO P OF INNER SILL is more than 1 , two of wood strip are not necessary. LOCATING UNIT IN WINDOW Open the window and mark center line on the center of the inner sill. O U T D O O OUTER R SILL S I N D O O R S 1 MAX. WO OD STRIP MO UNTED ON TO P OF INNER SILL STO RM WINDO W FRAME INNER SILL WOO D STRIP I FO R BASEPAN N ANGLE D O O R S CENTER LINE OUTER SILL O U T D O O R S ATTACH BASEPAN ANGLE Install the basepan angle behind the inner window sill, with the short side of basepan angle as shown. Use the 2 short screws13/ 32" provided. The basepan angle helps to hold unit securely in place. Be sure to place basepan angle edge flush against back of inner sill. INNER SILL INNER SILL 3/ 4 CLEARANCE SHORT SCREW13/ 32" CENTER LINE OUTER SILL IN SIDE 8 INDO OR SIDE SHORT SIDE 8 OUTSIDE BASEPAN ANGLE 9 Haier air conditioner Edition: 1.0-061231 Installation and Accessory Parts INSTALL THE AIR CONDITIONER IN THE WINDOW WINDOW FRAME UPPER GUIDE Carefully lift the air conditioner and slide it into the open window. Make sure the bottom guide of the air conditioner drops into the notches of the basepan angle. While steadying the air conditioner ,carefully bring the window sash down behind the upper guide of the air conditioner. ABOUT 1/ 4 BOTTOM GUIDE BASEPAN ANGLE INSTALL THE SEAL GASKET AND SASH LOCK WINDO W SEAL GASKET BASEPAN ANGLE SHORT SCREW13/ 32" Extend the side curtains to fill the window opening using 4 wood screws 31/ 32" to secure them. Cut the seal gasket to the window width. Stuff the sash seal between the glass and the window to prevent air and insects from getting into the room. Fasten the basepan angle, using a short screw13/ 32". WO OD SCREW31/ 32" 10 Haier air conditioner Installation and Accessory Parts wood screws 31/ 32" top rail ON/OFF MODE SPEED TIMER TEMP/TIME window seal gasket short screws 13/ 32" Remote control “ CR2025“ battery Model:HWR06XC5, ESA3055 11 Edition: 1.0-061231 Haier air conditioner Parts and Functions 12 Edition: 1.0-061231 Haier air conditioner Edition: 1.0-061231 Abnormity Diagnose 1. Sensor diagnose: 2 seconds after the sensors open circuit or short circuit, the unit will turn off automatically and the LED will show E0 until the sensors resume. 2. Keystroke circuit error diagnose: When power on for the first time, the PCB will check the keystroke circuit, if the sampling value is different with the theory value, the LED will show E1, which means failed keystroke circuit. The keyboard is locked and so invalid, but the remote control is working normally. 13 Haier air conditioner Edition: 1.0-061231 System Flow Chart Indoor heat exchanger Outdoor heat exchanger Compressor Capacillary tube Cooling 14 HIGH 1 ON 1 B (Plain) Y/G (G) W (Ribbed) B:BLACK Y:YELLOW GR:GREY R:RED G:GREEN POWER SUPPLY BL:BLUE Y/G:YELLOW/GREEN 0010552091 WIRING DIAGRAM SWITCH 1 OFF SWITCH 2 2 3 LOW 2 B L B ROOM THERMOSTAT C OVERLOAD RELAY R H L ~ GR R CAPACITOR M FAN MOTOR OR COMPRESSOR MR C ~ S W BL B HWR06XC6 ESA3056 CAPACITOR Note: Because of the difference of compressor, the dotted line part may not exist. 15 Edition: 1.0-061231 Haier air conditioner Wiring Diagram Haier air conditioner Edition: 1.0-061231 Sincere Forever Haier Group Haier Industrial Park, No.1, Haier Road 266101, Qingdao, China http://www.haier.com 16