Download 1 Push the
Transcript
List of check codes (outdoor unit) (Errors detected by SMMS outdoor interface typical examples) Check code Outdoor 7-segment display Sub-code TCC-LINK central control or main remote controller display E06 Number of indoor units from which signal is received normally E06 E07 — E08 Duplicated indoor address IPDU: Intelligent Power Drive Unit (Inverter P.C. board) Indoor unit (including Hot Water Module) Typical fault site Description of error Dropping out of indoor unit Indoor unit initially communicating normally fails to return signal (reduction in number of indoor units connected). (E04) Indoor-outdoor communication circuit error Signal cannot be transmitted to indoor units (indoor units left without communication from outdoor unit). (E08) Duplicated indoor address More than one indoor unit is assigned same address (also detected at indoor unit end). 01: Indoor-outdoor communication E12 02: Outdoor-outdoor communication E12 Automatic address starting error Indoor automatic address setting is started while automatic address setting for equipment in other refrigerant line is in progress. Outdoor automatic address setting is started while automatic address setting for indoor units is in progress. E15 E15 Indoor unit not found during automatic address setting Indoor unit fails to communicate while automatic address setting for indoor units is in progress. — E16 00: Overloading 01: Number of units connected E16 Too many indoor units connected / overloading Combined capacity of indoor units is too large (more than 135 % of combined capacity of outdoor units). ∗ E19 00: No header unit 02: Two or more header units E19 Error in number of outdoor header units There is no or more than one outdoor header unit in one refrigerant line. 01: Connection of outdoor unit from other refrigerant line E20 02: Connection of indoor unit from other refrigerant line E20 Connection to other refrigerant line found during automatic address setting Indoor unit from other refrigerant line is detected while indoor automatic address setting is in progress. E23 E23 Outdoor-outdoor communication transmission error Signal cannot be transmitted to other outdoor units. There is duplication in outdoor addresses set manually. — E25 — E25 Duplicated follower outdoor address E26 Address of outdoor unit from which signal is not received normally E26 Dropping out of outdoor unit Follower outdoor unit initially communicating normally fails to do so (reduction in number of follower outdoor units connected). E28 Outdoor follower unit error Outdoor header unit detects fault relating to follower outdoor unit (detail displayed on follower outdoor unit). E31 IPDU communication error There is no communication between IPDUs (P. C. boards) in inverter box. E28 Detected outdoor unit No. A3-IPDU Fan A3-IPDU Fan 1 01 O 02 03 O E31 04 05 O 06 07 O 08 09 O 2 3 IPDU O O O O OO OO O O 1 2 3 IPDU O 0A O O 0B O O 0C O O 0D O O O 0E O O O 0F O O O O Circle (O): Faulty IPDU F04 — F04 Outdoor discharge temperature sensor (TD1) error Outdoor discharge temperature sensor (TD1) has been open / short-circuited. F05 — F05 Outdoor discharge temperature sensor (TD2) error Outdoor discharge temperature sensor (TD2) has been open / short-circuited. Outdoor heat exchanger temperature sensor (TE1, TE2) error Outdoor liquid temperature sensor (TL) error Outdoor heat exchanger temperature sensors (TE1, TE2) have been open / short-circuited. Outdoor outside air temperature sensor (TO) error Outdoor outside air temperature sensor (TO) has been open / short-circuited. F06 01: TE1 02: TE2 F06 Outdoor liquid temperature sensor (TL) has been open / short-circuited. F07 — F07 F08 — F08 F11 — F11 F12 — F12 Outdoor suction temperature sensor (TS1) error Outdoor suction temperature sensor (TS1) has been open / short-circuited. 01: Compressor 1 F13 02: Compressor 2 03: Compressor 3 F13 Outdoor IGBT built-in temperature sensor (TH) error Open-circuit or short-circuit of the outdoor IGBT built-in temperature sensor (TH) was detected. F15 — F15 Outdoor temperature sensor (TE1, TL) wiring error Wiring error in outdoor temperature sensors (TE1, TL) has been detected. F16 — F16 Outdoor pressure sensor (Pd, Ps) Wiring error in outdoor pressure sensors (Pd, Ps) has been wiring error detected. F19 — F19 Indoor TF(TCJ2) sensor error • Check connection of TF sensor connector. • Check resistance characteristics of TF sensor. F22 — F22 Outdoor discharge temperature sensor (TD3) error Outdoor discharge temperature sensor (TD3) has been open / short-circuited. F23 — F23 Low pressure sensor (Ps) error Output voltage of low pressure sensor (Ps) is zero. ∗ When the indoor unit connection capacity is calculated, AP005 is calculated as 0.8 HP. – 40 –