Residential Packaged Units - 60Hz Puron®
R e v. : 4 J a n . , 2 0 1 2
Model Nomenclature: General Overview
1
2
3
4
5
6
7
8
9
10
11
12
5 0 Y E V 0 2 4 L C A 3 1 1
UNIT TYPE:
SIZE:
YE = GT-PG SINGLE-STAGE PURON® REFRIG
YD = GT-PX TWO-STAGE PURON® REFRIG
018
024
030
036
042
048
060
072
CONFIGURATION:
V = VERTICAL UPFLOW
H = HORIZONTAL
D = VERTICAL DOWNFLOW
AIR FLOW CONFIGURATION - ECM:
PACKAGING:
1 = SINGLE PACK, DOMESTIC
REVISION LEVEL:
1 = CURRENT REVISION
VOLTAGE:
3 = 208V, 230V/1PH/60Hz
AIR FLOW CONFIGURATION - PSC:
VERTICAL UPFLOW 50YD/50YE ONLY*
VERTICAL UPFLOW
HEAT EXCHANGER OPTIONS:
COATED AIR COIL
OPTION
RETURN
J
K
LEFT
RIGHT
DISCHARGE MOTOR
TOP
TOP
OPTION
RETURN
DISCHARGE
MOTOR
L
R
LEFT
RIGHT
TOP
TOP
PSC
PSC
ECM
ECM
VERTICAL DOWNFLOW
VERTICAL DOWNFLOW 50YD/50YE ONLY*
OPTION
RETURN
J
K
LEFT
RIGHT
DISCHARGE MOTOR
DOWN
DOWN
OPTION
RETURN
DISCHARGE
MOTOR
L
R
LEFT
RIGHT
DOWN
DOWN
PSC
PSC
ECM
ECM
COPPER
CUPRO-NICKEL
STANDARD
A
J
W/HOT WATER GENERATOR
B
K
WHOLE HOUSE DEHUMIDIFICATION
R
F
WHOLE HOUSE DEHUMIDIFICATION
W/HOT WATER GENERATOR
L
M
CONTROLS:
HORIZONTAL 50YD/50YE ONLY*
OPTION
RETURN
N
P
W
Y
RIGHT
RIGHT
LEFT
LEFT
DISCHARGE MOTOR
LEFT
BACK
RIGHT
BACK
C = CXM
HORIZONTAL
OPTION
RETURN
DISCHARGE
MOTOR
Z
B
S
E
RIGHT
RIGHT
LEFT
LEFT
LEFT
BACK
RIGHT
BACK
PSC
PSC
PSC
PSC
ECM
ECM
ECM
ECM
NOTE: YEV070 not available with PSC motor
NOTE: Some options/configurations not available on all series. Please consult Specification Catalogs for model specific options.
Rev.: Jan. 4, 2012
Safety
Warnings, cautions and notices appear throughout this
manual. Read these items carefully before attempting any
installation, service, or troubleshooting of the equipment.
DANGER: Indicates an immediate hazardous situation, which
if not avoided will result in death or serious injury. DANGER
labels on unit access panels must be observed.
WARNING: Indicates a potentially hazardous situation, which
if not avoided could result in death or serious injury.
WARNING!
WARNING! The Puron® Application and Service Manual
should be read and understood before attempting to
service refrigerant circuits with HFC-410A.
WARNING!
WARNING! To avoid the release of refrigerant into the
atmosphere, the refrigerant circuit of this unit must be
serviced only by technicians who meet local, state, and
federal proficiency requirements.
CAUTION: Indicates a potentially hazardous situation or an
unsafe practice, which if not avoided could result in minor or
moderate injury or product or property damage.
NOTICE: Notification of installation, operation or maintenance
information, which is important, but which is not hazardrelated.
WARNING!
WARNING! All refrigerant discharged from this unit must
be recovered WITHOUT EXCEPTION. Technicians must
follow industry accepted guidelines and all local, state,
and federal statutes for the recovery and disposal of
refrigerants. If a compressor is removed from this unit,
refrigerant circuit oil will remain in the compressor. To
avoid leakage of compressor oil, refrigerant lines of the
compressor must be sealed after it is removed.
CAUTION!
CAUTION! To avoid equipment damage, DO NOT use
these units as a source of heating or cooling during the
construction process. The mechanical components and
filters will quickly become clogged with construction dirt
and debris, which may cause system damage.
3