PDR-W839 6.8 SERVO ADJUSTMENT MANUAL ADJUSTMENT 6.8.1 Preparations 1. 2. 3. 4. Enter the TEST mode. Press the INPUT key so that "OPTICAL" appears on the FL display. Press the ERASE key more than three seconds to initialize it. Press the SYNCHRO key to perform the average process. \ "OPTICAL" disappears on the FL display when completed. 6.8.2 Focus Offset Adjustment Test Point CN102-pin 8 (Focus err) Adjustment Value 0 mV ± 30 mV Purpose Optimizing DC offset voltage of focus-error amplifier. Symptom when Out of Adjustment Focus-in does not function, or bad RF wave shape. Adjustment method FL Indication [Procedure] 1. Monitor the FOCUS ERROR waveform with VC. 2. Adjust the JOG key so that FE offset becomes zero. 3. Press the ENTER key to register the adjustment. CN102 FE 8 10: 1 prove Oscilloscope VC 6 6.8.3 SRFO Offset Adjustment Test Point CN102-pin 2 (RF) Adjustment Value 0 mV ± 30 mV Purpose Optimizing DC offset voltage of RFDC output circuit when recording. Symptom when Out of Adjustment Recording does not function. Adjustment method FL Indication [Procedure] 1. Press the AUTO SPACE key and shift to the SRFO Offset Adjustment. 2. Monitor the RFDC waveform with VC. 2. Adjust the JOG key so that RFDC offset becomes zero. 3. Press the ENTER key to register the adjustment. CN102 RF 2 10: 1 prove Oscilloscope VC 6 69