Download Appliance Specialty Study Guide
Transcript
e f g 44 a b c d e f g 45 a b c d e f g 46 a b c d 47 a b c d e f RVIA © 11/27/2011 --blower wheel --combustion wheel (intake air/blower) --combustion air hose --electrode assembly --DSI module board --wire and connections Check integrity of combustion chamber with CO detector Perform function test Verify DSI board shuts fan motor off (new style) Inspect and correct ducting and return air Verify amount of ducting, ducting area and static pressure to mfg. specs Check for restrictions, damaged ducts, air flow, loose/improper connections Check adjustable outlets to mfg. specs Verify return air area to mfg. specs Verify alignment/seal at plenum Measure voltage at furnace under load Verify wire size to mfg. specs Troubleshoot furnaces problems (Hydronic) Troubleshoot orifice issues Replace orifice Clean burner chamber Clean electric eye Replace ignition valve Replace mixing and zone valves Repair/replace pumps Troubleshoot furnace problems (all others) Troubleshoot voltage problems Troubleshoot propane pressure problems Troubleshoot ducting problems Troubleshoot air flow problem Install/repair/replace absorption refrigerators (Manual selection) Verify proper installation and venting per mfg. specs Verify AC and DC power sources per mfg. specs Verify propane pressure Verify leveling of refrigerator per mfg. specs Diagnose/replace electric components: --selector switch --electronic igniter --Piezo igniter --electrode --high voltage cable --relay --heating element (AC/DC) --thermostat --interior light and switch --fuses Diagnose/replace gas components: --shut off valve 8 of 51