Download Appliance Specialty Study Guide
Transcript
35 a b c d e f g 36 a b c d e f g h i j 37 a b c RVIA © 11/27/2011 Troubleshoot air conditioning problems Troubleshoot AC and DC voltage Troubleshoot freeze up Troubleshoot poor air flow; fan operation Troubleshoot erratic operation Troubleshoot no operation Troubleshoot electronics Troubleshoot drainage problems out of evaporator Repair/replace/install water heaters (Pilot) Visually inspect gas flame, burner tubes, thermocouple tightness, flue vents Verify gas pressure Troubleshoot sequence of operation and repair/replace various components --thermocouple --control valve --burner --pilot assembly --temperature and pressure relief valve --anode rod, if applicable --orifices (pilot and main burner) --ECO (energy cut off) Drain and flush water heater and inspect for calcium deposits --reestablish air pocket in tank Verify by-pass is in proper position (if applicable) Check fittings on tank Inspect/replace water tank --reseal flange Inspect/install/replace reigniter kit Verify air tight seal at gas line Perform function test Repair/replace/install water heaters (DSI-Direct Spark Ignition, 120 VAC, and Motor-Aid) Visually inspect gas flame, burner tube, flue box, and wires Verify gas pressure and voltage Troubleshoot sequence of operation and repair/replace various components --thermostat --ECO --control valve --burner --electrode assembly --temperature and pressure relief valve --anode rod, if applicable --DSI module board --main burner orifice --thermal cutoff --on/off switch --heating element --12VDC activated /120 VAC relay 5 of 51