Download RC2163BFE Instructions
Transcript
SETTING/OPERATING INSTRUCTIONS (Continued) RC2163FE IMPORTANT SAFETY INSTRUCTIONS When installing and operating this Product and other associated equipment, basic safety precautions should always be followed, including the following: 1. Read and follow all instructions. 2. This Control must be installed by a qualified electrician, according to National and Local Electrical Codes. 3. Install this control not less than 5 feet (3 meters in Canada) from inside edge of pool and 1 foot (30 cm) above ground. USE COPPER CONDUCTORS ONLY, rated Min. 70˚C. 4. Do not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors. 5. For Control grounding, bonding, installing and the wiring of underwater lights, refer to Article 680 of the National Electrical Code or Article 68 of the Canadian Electrical Code. 6. The Control should not operate any equipment which would cause bodily injury or property damage should it be activated unexpectedly. READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL INSTALLATION RC2163FE This Control can operate either a 120 volt or 240 volt, single speed pump, together with a gas heater and up to three 24 volt valve actuators. It has a 120 volt and 24 volt connection for a remote installed switching device and also has a connection for a freeze or heater protection device to turn ON the pump if needed. IMPORTANT: High and low voltage conductors should not occupy the same conduits or compartments. 1. Follow wiring diagram on Page 4 and prepare your Make sure the installation is securely grounded and installation layout. Make sure only copper (solid or bonded if required. stranded), 70˚C minimum rated conductors are used, properly sized and suitable for the installation. Each 5. Remove screw next to Heater Switch and gain piece of equipment must be grounded properly. access to printed circuit (P.C.) board assembly in IMPORTANT: Neutral must always be connected low voltage compartment. Follow wiring diagram on to the white lead of the control. page 4, plug valve actuators into designated sockets on P.C. board and make heater connections to ter2. Hang Control on a flat vertical surface or other minals 1, 2 and 3. support, using hardware suitable for the purpose. 3.Prepare the necessary conduit runs, including one for the remote - located 120 volt switching device (switch, timer or radio receiver), underwater light(s),* terminate them at both ends and pull-in the conductors as specified by the installation layout. *If this control is to be used for direct connection to under-water lights, a Nonmetallic Hub Kit should be used. Order 156PA13713A for a 1/2” Kit, 156PA13714A for a 3/4” Kit or 156PA13715A for a 1” Kit. Place jumper between terminals L and H if heater is single stage. See page 4 for details. Replace P.C. board assembly. 6. If selected, install remote - located low voltage control (Switch, or Timer). See wiring on page 4. 7. Check wiring, tightness of connections and grounding. Close wiring compartment and test installation. 8. Set timer, see instructions below. 4. Follow wiring diagram on page 4, make LINE and LOAD (Pump) connections in the high voltage compartment. To Review Program: Press TIMER key repeatedly. When done, press CLOCK key to return to the time of day. To Operate Equipment in Spa Mode: 1.Activate control. 2.After using the spa, make sure that control is back in the POOL mode. To Cancel/Change Part of the Program: Press Timer key repeatedly until the particular ON or OFF time appears. Set new ON or OFF time. To Operate Heater: Heater Selector Switch is provided to save on heating cost during the summer months or prevent over-heating of pool water if heater is the single thermostat type. Set switch to POOL AND SPA mode if the heater is the DUAL thermostat type and set thermostats on heater to the desired pool and spa water temperatures. Set switch to SPA ONLY mode if the heater is the SINGLE thermostat type or only the spa water needs to be heated. Set switch to OFF if no heater operation is needed. To Override the Automatic Operation one time: Press OVR. key to turn ON/OFF equipment. NOTE: Timer will resume automatic operation with the next opposite setpoint. To Suspend Automatic Operation Permanently: Press SELECT key to move indicator bar to the desired ON or OFF position. Note: Timer will not resume automatic operation until indicator bar is repositioned above the word AUTO. TROUBLESHOOTING Symptom Possible Cause(s) Corrective Action Control will not operate in SPA mode Defective remote control Defective relay Blown fuse Replace remote control Replace relay Replace fuse Timer is not turning pump ON/OFF for daily filtration Defective timer Defective relay Timer is set to ON/OFF No program in memory Dead battery Replace timer Replace relay Set timer to AUTO Set program - see instructions Replace battery Valve actuators(s) is/are not working Frozen valve Defective actuator Loose connection Blown fuse Check/Lubricate valve Replace actuator Check connections Replace fuse Pump inoperative Open circuit breaker Defective relay Defective pump Check power supply Change relay Check pump ENCLOSURE DETAILS SETTING / OPERATING INSTRUCTIONS Programming Instructions To Set or Change the Time of Day: To clear entire memory, press key. Hold down the CLOCK key while pressing either the HOUR or MINUTE keys. Continue pressing until the desired number is shown. Then simply lift finger off the CLOCK key to set. To Set Program (ON/OFF times): Press TIMER key once to enter into program mode. Display will show “1 ON-- --”. Press the HOUR key and then the MINUTE key to select the desired first ON time. Press TIMER key once. Display will show “1 OFF -- --”. Repeat previous step to select the desired first OFF time. Repeat the entire sequence to complete up to eight total ON/OFF times as desired. When programming is done, press the CLOCK key then the SELECT key repeatedly until the indicator bar is above the word “AUTO”. Display Reset port to cancel all prior settings 2 158AS11682 2 Indicator LED “ON” when connected to power source and contacts are closed ON/AUTO/OFF Select Key Function Keys RC2163BFE RC2163FE 3 3/18/09 4:24:42 PM