Download HCD-CL1/CL3
Transcript
HCD-CL1/CL3 CD player section System Laser Frequency response Tape deck section Recording system Frequency response Compact disc and digital audio system Semiconductor laser (λ=780 nm) Emission duration: continuous 2 Hz – 20 kHz (±0.5 dB) 4-track 2-channel stereo 40 – 13,000 Hz (±3 dB), using Sony TYPE I cassettes Tuner section FM stereo, FM/AM superheterodyne tuner FM tuner section Tuning range 87.5 – 108.0 MHz (50 kHz step) Antenna FM lead antenna Antenna terminals 75 ohms unbalanced Intermediate frequency 10.7 MHz AM tuner section Tuning range AEP models: 531 – 1,602 kHz (with the interval set at 9 kHz) Other models: 531 – 1,602 kHz (with the interval set at 9 kHz) 530 – 1,710 kHz (with the interval set at 10 kHz) Antenna AM loop antenna External antenna terminals Intermediate frequency 450 kHz General Power requirements North American model: 120 V AC, 60 Hz AEP models: 230 V AC, 50/60 Hz Australian and New Zealand models: 230 – 240 V AC, 50/ 60 Hz Mexican model: 120 V AC, 60 Hz Korean model: 220 V AC, 60 Hz Other models: 120 V, 220 V, 230 – 240 V AC, 50/60 Hz Adjustable with voltage selector Power consumption U.S.A. model: HCD-CL1: 100 watts AEP models: HCD-CL3: 165 watts HCD-CL1: 100 watts HCD-CL3/CL1: 0.5 watts (at the Power Saving Mode) Other models: HCD-CL3: 165 watts HCD-CL1: 100 watts Dimensions (w/h/d) incl. projecting parts and controls Approx. 215 × 285 × 421 mm Mass Amplifier/Tuner/Tape/CD section: HCD-CL3: Approx. 8.0 kg HCD-CL1: Approx. 7.7 kg Design and specifications are subject to change without notice. 2 SAFETY CHECK-OUT After correcting the original service problem, perform the following safety checks before releasing the set to the customer: Check the antenna terminals, metal trim, “metallized” knobs, screws, and all other exposed metal parts for AC leakage. Check leakage as described below. LEAKAGE The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microamperes). Leakage current can be measured by any one of three methods. 1. A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturers’ instructions to use these instruments. 2. A battery-operated AC milliammeter. The Data Precision 245 digital multimeter is suitable for this job. 3. Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The “limit” indication is 0.75 V, so analog meters must have an accurate low-voltage scale. The Simpson 250 and Sanwa SH-63Trd are examples of a passive VOM that is suitable. Nearly all battery operated digital multimeters that have a 2V AC range are suitable. (See Fig. A) To Exposed Metal Parts on Set 0.15 µF 1.5 kΩ AC Voltmeter (0.75 V) Earth Ground Fig. A. Using an AC voltmeter to check AC leakage.