SECTION 2
Features & Specifications
Regional Control Processor (RCP02e)
DESCRIPTION
POWER REQUIREMENTS (operational) - DC ONLY
OPERATING TEMPERATURE RANGE
OPERATING HUMIDITY RANGE
MAXIMUM number of TSC Sites
MAXIMUM number of PSTN phone lines
MAXIMUM number of PABX phone lines
MAXIMUM number of VDU Line Dispatchers
MAXIMUM number of Inter-regional gateways
MAXIMUM number of PCM switch interfaces
MAXIMUM number of System Terminal interfaces
MAXIMUM number of simultaneous speech calls
All INTERFACE TYPES
APPROVALS
......
......
......
......
......
......
......
......
......
......
......
......
......
SPECIFICATION
+10 to 18VDC @ .5A
-10°C to + 70°C
10% to 90% n/c.
10
24
24 on 8 exchanges
16
1
1
2
64
RS232 - 9 way D-type
EMC Directive 89/336/EEC(143)
Single Site Interconnect Unit (part of SSTAK)
DESCRIPTION
POWER REQUIREMENTS (operational) DC ONLY
OPERATING TEMPERATURE RANGE
OPERATING HUMIDITY RANGE
MAXIMUM number of TSC Sites
MAXIMUM number of PSTN phone lines
MAXIMUM number of PABX phone lines
MAXIMUM number of VDU Line Dispatchers
MAXIMUM number of Inter-regional gateways
MAXIMUM number of PCM switch interfaces
MAXIMUM number of System Terminal interfaces
MAXIMUM number of simultaneous speech calls
......
......
......
......
......
......
......
......
......
......
......
All INTERFACE TYPES
APPROVALS
......
......
SPECIFICATION
+10 to 18VDC @ .5A
-10°C to + 70°C
10% to 90% n/c.
1
24
24 on 8 exchanges
16
0
1
1
39 (23 traffic channels and 16
VDU despatchers).
RS232 - 9 way D-type
EMC Directive 89/336/EEC(143)
Inter-Regional Processor
DESCRIPTION
POWER REQUIREMENTS - AC ONLY
OPERATING TEMPERATURE RANGE
OPERATING HUMIDITY RANGE
MAXIMUM number of Regional Interfaces
MAXIMUM number of speech ccts. per region
MAXIMUM number of PCM switch interfaces
MAXIMUM number of Diagnostic Terminals
MAXIMUM number of simultaneous speech calls
......
......
......
......
......
......
......
......
All INTERFACE TYPES
ADVANTECH industrial PC chassis
......
......
SPECIFICATION
110/240VAC @ 500VA
0°C to + 55°C
10% to 90% n/c.
16
24
1 (optional)
1
64
(128 port switch capacity ÷ 2)
RS232 - 25 way D-type
EMC Directive
89/336/EEC(143)
© Fylde Microsystems Ltd. Technical Description of FyldeSuperTrunk