Download Fylde Infrastructure
Transcript
SECTION 2 Features & Specifications Regional Control Processor (RCP02e) DESCRIPTION POWER REQUIREMENTS (operational) - DC ONLY OPERATING TEMPERATURE RANGE OPERATING HUMIDITY RANGE MAXIMUM number of TSC Sites MAXIMUM number of PSTN phone lines MAXIMUM number of PABX phone lines MAXIMUM number of VDU Line Dispatchers MAXIMUM number of Inter-regional gateways MAXIMUM number of PCM switch interfaces MAXIMUM number of System Terminal interfaces MAXIMUM number of simultaneous speech calls All INTERFACE TYPES APPROVALS ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... SPECIFICATION +10 to 18VDC @ .5A -10°C to + 70°C 10% to 90% n/c. 10 24 24 on 8 exchanges 16 1 1 2 64 RS232 - 9 way D-type EMC Directive 89/336/EEC(143) Single Site Interconnect Unit (part of SSTAK) DESCRIPTION POWER REQUIREMENTS (operational) DC ONLY OPERATING TEMPERATURE RANGE OPERATING HUMIDITY RANGE MAXIMUM number of TSC Sites MAXIMUM number of PSTN phone lines MAXIMUM number of PABX phone lines MAXIMUM number of VDU Line Dispatchers MAXIMUM number of Inter-regional gateways MAXIMUM number of PCM switch interfaces MAXIMUM number of System Terminal interfaces MAXIMUM number of simultaneous speech calls ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... All INTERFACE TYPES APPROVALS ...... ...... SPECIFICATION +10 to 18VDC @ .5A -10°C to + 70°C 10% to 90% n/c. 1 24 24 on 8 exchanges 16 0 1 1 39 (23 traffic channels and 16 VDU despatchers). RS232 - 9 way D-type EMC Directive 89/336/EEC(143) Inter-Regional Processor DESCRIPTION POWER REQUIREMENTS - AC ONLY OPERATING TEMPERATURE RANGE OPERATING HUMIDITY RANGE MAXIMUM number of Regional Interfaces MAXIMUM number of speech ccts. per region MAXIMUM number of PCM switch interfaces MAXIMUM number of Diagnostic Terminals MAXIMUM number of simultaneous speech calls ...... ...... ...... ...... ...... ...... ...... ...... All INTERFACE TYPES ADVANTECH industrial PC chassis ...... ...... SPECIFICATION 110/240VAC @ 500VA 0°C to + 55°C 10% to 90% n/c. 16 24 1 (optional) 1 64 (128 port switch capacity ÷ 2) RS232 - 25 way D-type EMC Directive 89/336/EEC(143) © Fylde Microsystems Ltd. Technical Description of FyldeSuperTrunk 21